AimsTo collect information on the use of the Reveal implantable loop recorder (ILR) in the patient care pathway and to investigate its effectiveness in the diagnosis of unexplained recurrent syncope in everyday clinical practice.Methods and resultsProspective, multicentre, observational study conducted in 2006–2009 in 10 European countries and Israel. Eligible patients had recurrent unexplained syncope or pre-syncope. Subjects received a Reveal Plus, DX or XT. Follow up was until the first recurrence of a syncopal event leading to a diagnosis or for ≥1 year. In the course of the study, patients were evaluated by an average of three different specialists for management of their syncope and underwent a median of 13 tests (range 9–20). Significant physical trauma had been experienced in association with a syncopal episode by 36% of patients. Average follow-up time after ILR implant was 10 ± 6 months. Follow-up visit data were available for 570 subjects. The percentages of patients with recurrence of syncope were 19, 26, and 36% after 3, 6, and 12 months, respectively. Of 218 events within the study, ILR-guided diagnosis was obtained in 170 cases (78%), of which 128 (75%) were cardiac.ConclusionA large number of diagnostic tests were undertaken in patients with unexplained syncope without providing conclusive data. In contrast, the ILR revealed or contributed to establishing the mechanism of syncope in the vast majority of patients. The findings support the recommendation in current guidelines that an ILR should be implanted early rather than late in the evaluation of unexplained syncope.
Limited prospective data are available regarding the influence of pacemaker leads on tricuspid valve function. To examine the true incidence of these complications, 35 patients were prospectively examined by two-dimensional and Doppler echocardiography before and after implantation of either a permanent pacemaker or an automatic implantable cardioverter-defibrillator. Of the 35 patients imaged preoperatively, the amount of tricuspid regurgitation (TR) was judged as normal or trivial in 15 (43%), mild in 10 (29%), moderate in 8 (23%), and severe in 2 (6%). Following electrode implantation, TR was noted to be normal or trivial in 13 (38%), mild in 15 (48%), moderate in 6 (17%) and severe in 1 (3%). We conclude that implantation of permanent right ventricular electrodes is not usually associated with an acute worsening of tricuspid regurgitation in most patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.