Continuous-flow inlets from oxidation reactors are commonly used systems for biological sample introduction into isotope ratio mass spectrometers (IRMS) to measure 13C enrichment above natural abundance. Because the samples must be volatile enough to pass through a gas chromatograph, silylated derivatization reactions are commonly used to modify biological molecules to add the necessary volatility. Addition of a tert-butyldimethylsilyl (TBDMS) group is a common derivatization approach. However, we have found that samples do not produce the expected increment in measured 13C abundance as the TBDMS derivatives. We have made measurements of 13C enrichment of leucine and glutamate standards of known 13C enrichment using derivatives without silicon (N-acetyl n-propyl ester), with silicon (TBDMS), and an intermediate case. The measurements of 13C in amino acids derivatized without silicon were as expected. The 13C enrichment measurements using the TBDMS derivative were higher than expected but could be corrected to produce the expected 13C enrichment measurement by IRMS if one carbon was removed per silicon. We postulate that the silicon in the derivative forms silicon carbide compounds in the heated cupric oxide reactor, rather than forming silicon dioxide. Doing so reduces the amount of CO2 formed from the carbon in the sample. Silylated derivatives retain carbon with the silicon and must be used carefully and with correction factors to measure 13C enrichments by continuous-flow IRMS.
[1,2-(13)C(2)]glutamine and [ring-(2)H(5)]phenylalanine were infused for 7 h into five postabsorptive healthy subjects on two occasions. On one occasion, the tracers were infused intravenously for 3.5 h and then by a nasogastric tube for 3.5 h. The order of infusion was reversed on the other occasion. From the plasma tracer enrichment measurements at plateau during the intravenous and nasogastric infusion periods, we determined that 27 +/- 2% of the enterally delivered phenylalanine and 64 +/- 2% of the glutamine were removed on the first pass by the splanchnic bed. Glutamine flux was 303 +/- 8 micromol. kg(-1). h(-1). Of the enterally delivered [(13)C]glutamine tracer, 73 +/- 2% was recovered as exhaled CO(2) compared with 58 +/- 1% of the intravenously infused tracer. The fraction of the enterally delivered tracer that was oxidized specifically on the first pass by the splanchnic bed was 53 +/- 2%, comprising 83% of the total tracer extracted. From the appearance of (13)C in plasma glucose, we estimated that 7 and 10% of the intravenously and nasogastrically infused glutamine tracers, respectively, were converted to glucose. The results for glutamine flux and first-pass extraction were similar to our previously reported values when a [2-(15)N]glutamine tracer [Matthews DE, Morano MA, and Campbell RG, Am J Physiol Endocrinol Metab 264: E848-E854, 1993] was used. The results of [(13)C]glutamine tracer disposal demonstrate that the major fate of enteral glutamine extraction is for oxidation and that only a minor portion is used for gluconeogenesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.