Transarterial embolization of direct carotid-cavernous fistulas (CCFs) using detachable balloons is the best initial option for occlusion of the fistula and preservation of the internal carotid artery. However, the long-term safety and efficacy of this treatment is unknown. The authors reviewed the long-term outcome of 87 patients with 88 direct CCFs occluded by detachable balloons. Clinical follow up was obtained in 48 (83%) of 58 patients treated with latex balloons (mean follow-up period 10 years, range 5.9-15.5 years) and 28 (97%) of 29 patients treated with silicone balloons (mean follow-up period 4 years, range 1-6.6 years). Two patients were treated with both balloon types. There were no late recurrent symptoms of cranial bruit, proptosis, chemosis, or arterialized conjunctiva in patients treated with either latex or silicone balloons. Diplopia improved in all patients; however, five patients required shortening of the lateral rectus muscle. Delayed ischemia occurred in three patients: one patient had a transient ischemic episode 5 years after treatment with latex balloons and two patients (85 and 90 years old) who had ruptured spontaneous intracavernous aneurysms suffered cerebral infarctions 6 weeks and 4 months, respectively, after treatment with silicone balloons. There were five deaths in the series unrelated to balloon treatment. These results show that after transarterial embolization of direct CCFs using either silicone or latex detachable balloons, the long-term risks are low for fistula recurrence, symptomatic foreign body reaction, symptomatic pseudoaneurysm formation, and cerebral ischemia.
BackgroundIndependence from all optical aids, and freedom from unwanted symptoms, following cataract and lens surgery remains the ultimate goal of both patient and surgeon. The development of trifocal IOL technology provides an ever-increasing range of options. The purpose of our study is to understand the predictability, safety and efficacy of a new trifocal intraocular lens (IOL) following cataract or refractive lens exchange (RLE) surgery.MethodsThis was a retrospective consecutive case series of patients undergoing cataract extraction or RLE followed by implantation of the Alcon IQ Panoptix IOL. Pre and postoperative refractive and visual parameters were recorded and evaluated. As the cohort followed a normal distribution, standard parametric tests were used. Paired t-test was used to compare the difference between target and postoperative refractive errors. The incidence of intraoperative and postoperative complications was also reported.ResultsThe IOL was implanted in 66 eyes of 33 patients. Mean postoperative spherical equivalent (SE) refraction was -0.08 ± 0.25 dioptres (D). This was not significantly different from the target refraction (p = 0.841). Sixty-five percent of patients were within ± 0.25 D of the target SE refraction with 100% within ± 0.50 D of intended correction. Mean postoperative uncorrected distance visual acuity (UDVA) was 0.01 ± 0.10 LogMAR. All patients achieved an unaided distance acuity of 20/40 or better postoperatively. Binocularly, 100% saw 0.20 LogMAR or better at near without correction and 88.9% achieved this level for uncorrected intermediate visual acuity. No intraoperative complications were noted. Five patients complained of moderate haloes in the early postoperative period.ConclusionThe AcrySof IQ Panoptix IOL provides functional uncorrected visual acuity at distance, intermediate and near positions. Our results remain equivalent with existing trifocal IOL outcomes and provide surgeons with a further IOL alternative for the patient motivated to obtain true spectacle independence. Surgeons should consider individual reading and working requirements when counselling patients preoperatively to optimise postoperative patient satisfaction.Electronic supplementary materialThe online version of this article (doi:10.1186/s40662-017-0076-8) contains supplementary material, which is available to authorized users.
No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.