The acid ionization constant, K a , of acetic acid and the base ionization constant, K b , of ammonia are determined easily and rapidly using a datalogger, a pH sensor, and a conductivity sensor. To decrease sample preparation time and to minimize waste, sequential aliquots of a concentrated standard are added to a known volume of water and measurements are made after each addition. In this laboratory exercise, students show that K a and K b are constants, compare and contrast pH and conductivity approaches, and evaluate how solution components (weak acid alone and weak acid plus conjugate base) affect the results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.