BackgroundWe present the first phase contrast (PC) cardiovascular magnetic resonance (CMR) measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG).MethodsA validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30–39 weeks). Flow was measured in the major fetal vessels and indexed to the fetal weight.ResultsThere was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96). Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO) 540±101, main pulmonary artery (MPA) 327±68, ascending aorta (AAo) 198±38, superior vena cava (SVC) 147±46, ductus arteriosus (DA) 220±39,pulmonary blood flow (PBF) 106±59,descending aorta (DAo) 273±85, umbilical vein (UV) 160±62, foramen ovale (FO)107±54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60±4, AAo37±4, SVC 28±7, DA 41±8, PBF 19±10, DAo50±12, UV 30±9, FO 21±12.ConclusionThis study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.
Phase-contrast magnetic resonance imaging can be used to complement echocardiography for the evaluation of the fetal heart. Cardiac imaging typically requires gating with peripheral hardware; however, a gating signal is not readily available in utero. No successful application of existing technologies to human fetal phase-contrast magnetic resonance imaging has been reported to date in the literature. The purpose of this work is to develop a technique for phase-contrast magnetic resonance imaging of the fetal heart that does not require measurement of a gating signal. Metric optimized gating involves acquiring data without gating and retrospectively determining the proper reconstruction by optimizing an image metric. The effects of incorrect gating on phase contrast images were investigated, and the time-entropy of the series of images was found to provide a good measure of the level of corruption. The technique was validated with a pulsatile flow phantom, experiments with adult volunteers, and in vivo application in the fetal population. Images and flow curves from these measurements are presented. Additionally, numerical simulations were used to investigate the degree to which heart rate variability affects the reconstruction process. Metric optimized gating enables imaging with conventional phase-contrast magnetic resonance imaging sequences in the absence of a gating signal, permitting flow measurements in the great vessels in utero. Magn Reson Med 64:1304-1314,
Selection bias In a recent research article in CMAJ, 1 the study population consists entirely of ill travellers self-reporting to a travel clinic upon their return. It seems likely that this would select patients who were either sufficiently unwell or sufficiently worried about their illness to seek medical attention. In light of this, I find it unsurprising that this study 1 observed a higher incidence of complicated disease than that seen in endemic areas.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.