PurposeTo investigate and compare the quantitative accuracy of 90Y imaging across different generation PET/CT scanners, for the purpose of dosimetry after radioembolization with resin microspheres.MethodsA strict experimental and imaging protocol was followed by 47 international sites using the NEMA 2007/IEC 2008 PET body phantom with an 8-to-1 sphere-to-background ratio of 90Y solution. The phantom was imaged over a 7-day period (activity ranging from 0.5 to 3.0 GBq) and all reconstructed data were analysed at a core laboratory for consistent processing. Quantitative accuracy was assessed through measures of total phantom activity, activity concentration in background and hot spheres, misplaced counts in a nonradioactive insert, and background variability.ResultsOf the 69 scanners assessed, 37 had both time-of-flight (ToF) and resolution recovery (RR) capability. These current generation scanners from GE, Philips and Siemens could reconstruct background concentration measures to within 10 % of true values over the evaluated range, with greater deviations on the Philips systems at low count rates, and demonstrated typical partial volume effects on hot sphere recovery, which dominated spheres of diameter <20 mm. For spheres >20 mm in diameter, activity concentrations were consistently underestimated by about 20 %. Non-ToF scanners from GE Healthcare and Siemens were capable of producing accurate measures, but with inferior quantitative recovery compared with ToF systems.ConclusionCurrent generation ToF scanners can consistently reconstruct 90Y activity concentrations, but they underestimate activity concentrations in small structures (≤37 mm diameter) within a warm background due to partial volume effects and constraints of the reconstruction algorithm. At the highest count rates investigated, measures of background concentration (about 300 kBq/ml) could be estimated on average to within 1 %, 5 % and 2 % for GE Healthcare (all-pass filter, RR + ToF), Philips (4i8s ToF) and Siemens (2i21s all-pass filter, RR + ToF) ToF systems, respectively. Over the range of activities investigated, comparable performance between GE Healthcare and Siemens ToF systems suggests suitability for quantitative analysis in a scenario analogous to that of postradioembolization imaging for treatment of liver cancer.
Our studies have identified a soluble molecule in normal human plasma and serum with the characteristics of the ␣-chain of the low density lipoprotein receptorrelated protein (LRP). LRP is a large multifunctional receptor mediating the clearance of diverse ligands, including selected lipoproteins, various protease inhibitor complexes, and thrombospondin. A soluble molecule (sLRP) has been isolated from plasma using an affinity matrix coupled with methylamine-activated ␣ 2 -macroglobulin, the ligand uniquely recognized by LRP, and eluted with EDTA. This eluate contains a protein that co-migrates on SDS-polyacrylamide gel electrophoresis with authentic human placental LRP ␣-chain, is recognized by anti-LRP ␣-chain monoclonal antibodies, and binds the 39-kDa receptor-associated protein (RAP) and tissue plasminogen activator-inhibitor complexes. A similar RAP-binding molecule was detected in medium conditioned for 24 h by primary cultures of rat hepatocytes, suggesting that the liver may be the in vivo source of sLRP. In contrast, immunoprecipitation experiments failed to detect the production of sLRP by cultured HepG2 hepatoma and primary human fibroblast cells. Addition of a soluble form of LRP to cultured HepG2 cells resulted in a significant inhibition of capacity of these cells to degrade tPA, a process that has been demonstrated to be mediated by cell surface LRP. Preliminary data indicate that the concentration of sLRP is altered in the plasma of patients with liver disease. Increased levels of sLRP may antagonize the clearance of ligands by cell bound LRP perturbing diverse processes including lipid metabolism, cell migration and extracellular proteinase activity.The low density lipoprotein receptor-related protein (LRP) 1 has been previously identified as a membrane-bound endocytic receptor (1, 2). Studies have demonstrated that LRP mediates the internalization of multiple, structurally unrelated ligands, including selected lipoproteins, proteinase-inhibitor complexes, plasminogen activators, and thrombospondin (reviewed in Refs. 3 and 4). The binding of all ligands to LRP is inhibited by the receptor-associated protein (RAP), a protein that was copurified with LRP (2, 5). The range of ligands recognized by LRP suggests that it plays a role in diverse processes including lipid metabolism, cell growth, migration, and tissue invasion. LRP expression is widespread; however, it is most highly expressed in the liver, brain, and placenta. The remarkable degree of cross-species identity conserved in the LRP amino acid sequence (3) and the embryonic lethal phenotype obtained after targeted disruption of the LRP gene in the mouse (6) underscore the biological importance of this molecule.Here we report the identification of a soluble form of LRP circulating in human plasma. The characterization of this molecule, which maintains the ligand binding characteristics of cell surface LRP, introduces a new dimension to the biology of LRP. Accumulation of soluble LRP in plasma may antagonize the clearance of ligands by cell-...
Concomitant use of radioembolization plus irinotecan did not reach a maximum-tolerated dose. The recommended dose of irinotecan in this setting is 100 mg/m(2) on days 1 and 8 of a 3-week cycle.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.