The StARkin superfamily comprises proteins with steroidogenic acute regulatory protein-related lipid transfer (StART) domains that are implicated in intracellular, non-vesicular lipid transport. A new family of membrane-anchored StARkins was recently identified, including six members, Lam1-Lam6, in the yeast Lam1-Lam4 are anchored to the endoplasmic reticulum (ER) membrane at sites where the ER is tethered to the plasma membrane and proposed to be involved in sterol homeostasis in yeast. To better understand the biological roles of these proteins, we carried out a structure-function analysis of the second StARkin domain of Lam4, here termed Lam4S2. NMR experiments indicated that Lam4S2 undergoes specific conformational changes upon binding sterol, and fluorescence-based assays revealed that it catalyzes sterol transport between vesicle populations, exhibiting a preference for vesicles containing anionic lipids. Using such vesicles, we found that sterols are transported at a rate of ∼50 molecules per Lam4S2 per minute. Crystal structures of Lam4S2, with and without bound sterol, revealed a largely hydrophobic but surprisingly accessible sterol-binding pocket with the 3-OH group of the sterol oriented toward its base. Single or multiple alanine or aspartic acid replacements of conserved lysine residues in a basic patch on the surface of Lam4S2 near the likely sterol entry/egress site strongly attenuated sterol transport. Our results suggest that Lam4S2 engages anionic membranes via a basic surface patch, enabling "head-first" entry of sterol into the binding pocket followed by partial closure of the entryway. Reversal of these steps enables sterol egress.
Blood coagulation analysis is characterized by the application of a variety of materials, reagents, and analyzers for the determination of the same parameter, or analyte, by different laboratories worldwide. Accordingly, the application of common reference intervals, that, by definition, would represent a “range of values (of a certain analyte) that is deemed normal for a physiological measurement in healthy persons,” is difficult to implement without harmonization of procedures. In fact, assay-specific reference intervals are usually established to allow for the discrimination of normal and abnormal values during evaluation of patient results. While such assay-specific reference intervals are often determined by assay manufacturers and subsequently adopted by customer laboratories, verification of transferred values is still mandatory to confirm applicability on site. The same is true for reference intervals that have been adopted from other laboratories, published information, or determined by indirect data mining approaches. In case transferable reference intervals are not available for a specific assay, a direct recruiting approach may or needs to be applied. In comparison to transferred reference interval verification, however, the direct recruiting approach requires a significantly higher number of well-defined samples to be collected and analyzed. In the present review, we aim to give an overview on the above-mentioned aspects and procedures, also with respect to relevant standards, regulations, guidelines, but also challenges for both, assay manufacturers and coagulation laboratories.
Der I. Zivilsenat des BGH hat im April entschieden, dass die näheren Angaben, die bei einem Verbrauchsgüterkauf in der Garantieerklärung enthalten sein müssen, nicht notwendig schon in der Werbung mit der Garantie aufgeführt werden müssen. Anlässlich dieser Entscheidung befasst sich der folgende Beitrag mit den Rahmenbedingungen für Werbung mit Garantieversprechen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.