Percutaneous iliosacral screw fixation is a widely accepted method of stabilizing the posterior pelvic ring. Recently developed tools such as 3D-navigated fluoroscopy and computed navigation seem to prevent a surgeon from conducting screw misplacement. The study aimed to comparatively assess the introduction of sacroiliac screw placement using 2D and 3D fluoroscopy in terms of accuracy and radiation exposure. Iliosacral screws were introduced in 37 patients using 2D (group N1) and in 36 patients using 3D fluoroscopy (group N2) techniques. Overall, 61 and 56 screws were introduced in groups N1 and N2, respectively. Screw placement accuracy was assessed using postoperative computed tomography and Smith’s scale. Intraoperative radiation exposure was also assessed. No differences were noted between groups in terms of screw positioning accuracy and radiation dose. Both 2D and 3D fluoroscopy provide good visualization for safely placing percutaneous iliosacral joint screws. Using 3D fluoroscopy-based navigation in comparison with 2D fluoroscopy is not advantageous.
The study retrospectively determined the efficacy and safety of fixation of the pelvis (FFP) fragility fractures type IV using two tension band ilioiliac locking compression plates. Forty-one patients with FFP were treated in 2017–2020. 16 patients with FFP type IV, unable to walk weight-bearing, were treated by fixation using two tension band ilioiliac locking compression plates without fixing the anterior ring. Preoperatively and one year postoperatively, the functional outcome and performance were assessed using Pelvic Discomfort Index (PDI) and Timed Up and Go (TUG) test. Pre- and postoperative hemoglobin level was evaluated. Operation time and intra-and postoperative complications were documented. One year postoperatively, an X-ray was taken. The arithmetic mean (x) and standard deviations (±) of quantitative variables were calculated. T-test for dependent samples was used for pre-and postoperative results comparison. The PDI improved (p < 0.001) from x = 81.42 ± 4.04 to x = 36.19 ± 15.58. Preoperatively none of the patients was able to perform the TUG test. Postoperatively, the result exceeded x = 13.13 ± 3.99 s. The operation lasted x = 42.80 ± 8.90 min. Hemoglobin decreased (p < 0.001) from 11.63 ± 1.11 to 9.07 ± 1.21 g/dL. No complications nor fixation loosening were noted. The study support fixation using two tension band ilioiliac locking compression plates as an efficient and safe treatment of the FFP type IV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.