Background: Infection remains among the main reasons for joint prosthesis failure. Preclinical reports have suggested that antibacterial coatings of implants may prevent bacterial adhesion and biofilm formation. This study presents the results of the first clinical trial on an antibiotic-loaded fast-resorbable hydrogel coating (Defensive Antibacterial Coating, DAC®) in patients undergoing hip or knee prosthesis.Methods: In this multicenter, randomized prospective study, a total of 380 patients, scheduled to undergo primary (n=270) or revision (n=110) total hip (N=298) or knee (N=82) joint replacement with a cementless or a hybrid implant, were randomly assigned, in six European orthopedic centers, to receive an implant either with the antibiotic-loaded DAC coating (treatment group) or without coating (control group). Pre- and postoperative assessment of clinical scores, wound healing, laboratory tests, and x-ray exams were performed at fixed time intervals.Results: Overall, 373 patients were available at a mean follow-up of 14.5 ± 5.5 months (range 6 to 24). On average, wound healing, laboratory and radiographic findings showed no significant difference between the two groups. Eleven early surgical site infections were observed in the control group and only one in the treatment group (6% vs. 0.6%; p=0.003). No local or systemic side effects related to the DAC hydrogel coating were observed, and no detectable interference with implant osteointegration was noted.Conclusions: The use of a fast-resorbable, antibiotic-loaded hydrogel implant coating can reduce the rate of early surgical site infections, without any detectable adverse events or side effects after hip or knee joint replacement with a cementless or hybrid implant.
BackgroundSymptomatic hardware represents the most frequent complication reported following surgical treatment of patellar fracture. For this reason, some authors suggested using nonabsorbable sutures to fix the fracture with various techniques. The aim of this study was to evaluate clinical and radiological results of patients treated following a modified Pyriford technique using a FiberWire suture (Arthrex, Naples, FL, USA).Materials and methodsWe retrospectively evaluated a case series of seventeen patients with displaced patellar fractures treated by open reduction and internal fixation with a modified tension band using FiberWire sutures. Clinical and radiological outcome were evaluated. Union time, complications, and reoperation rate were observed and recorded.ResultsAll fractures healed (time to union 9.2 ± 2 weeks), and no fixation failure was observed. Slight losses of reduction (<4 mm) were noted in two patients at 4 weeks postoperatively. The average Lysholm and Bostman scores at the final follow-up were 91 ± 5.7 (range 83–100) and 28.3 ± 1.6 (range 26–30), respectively.ConclusionModified tension band using FiberWire sutures showed satisfactory clinical results, with a low incidence of complications and reoperations. FiberWire tension bands could be used in place of metal-wire tension bands to treat patellar fracture, reducing the rate of symptomatic hardware.Level of evidence4
IntroductionWe aimed to assess the incidence and hospitalization rate of hip and "minor" fragility fractures in the Italian population.MethodsWe carried out a 3-year survey at 10 major Italian emergency departments to evaluate the hospitalization rate of hip, forearm, humeral, ankle, and vertebral fragility fractures in people 45 years or older between 2004 and 2006, both men and women. These data were compared with those recorded in the national hospitalizations database (SDO) to assess the overall incidence of fragility fractures occurring at hip and other sites, including also those events not resulting in hospital admissions.ResultsWe observed 29,017 fractures across 3 years, with hospitalization rates of 93.0% for hip fractures, 36.3% for humeral fractures, 31.3% for ankle fractures, 22.6% for forearm/wrist fractures, and 27.6% for clinical vertebral fractures. According to the analyses performed with the Italian hospitalization database in year 2006, we estimated an annual incidence of 87,000 hip, 48,000 humeral, 36,000 ankle, 85,000 wrist, and 155,000 vertebral fragility fractures in people aged 45 years or older (thus resulting in almost 410,000 new fractures per year). Clinical vertebral fractures were recorded in 47,000 events per year.ConclusionsThe burden of fragility fractures in the Italian population is very high and calls for effective preventive strategies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.