A collaboration that grew over time between local hemovigilance stakeholders and the Massachusetts Department of Public Health (MDPH) resulted in the change from a paper-based method of reporting adverse reactions and monthly transfusion activity for regulatory compliance purposes to statewide adoption of electronic reporting via the National Healthcare Safety Network (NHSN). The NHSN is a web-based surveillance system that offers the capacity to capture transfusion-related adverse events, incidents, and monthly transfusion statistics from participating facilities. Massachusetts' hospital blood banks share the data they enter into NHSN with the MDPH to satisfy reporting requirements. Users of the NHSN Hemovigilance Module adhere to specified data entry guidelines, resulting in data that are comparable and standardized. Keys to successful statewide adoption of this reporting method include the fostering of strong partnerships with local hemovigilance champions and experts, engagement of regulatory and epidemiology divisions at the state health department, the leveraging of existing relationships with hospital NHSN administrators, and the existence of a regulatory deadline for implementation. Although limitations exist, successful implementation of statewide use of the NHSN Hemovigilance Module for hospital blood bank reporting is possible. The result is standardized, actionable data at both the hospital and state level that can facilitate interfacility comparisons, benchmarking, and opportunities for practice improvement.
Background While studies have shown that antibody detection may be delayed if an antibody identification (ABID) is not performed every 3 days, little data exist on the potential major risk of an acute hemolytic transfusion reaction (aHTR). Study Design and Methods At our institution, if no change in the screen, or a positive crossmatch, ABIDs are performed every 30 days. Between January 1, 2015 and May 31, 2019, all new antibodies detected within 28 days of a prior transfusion were identified. Testing results and patient charts were reviewed for evidence of hemolysis. The $211 patient charge was used to determine the cost for ABIDs performed during the studied time period. Results For 36 patients, a new clinically significant alloantibody was detected within 28 days of an antigen‐positive transfusion. Only one of these patients had a history of prior alloimmunization and put at possible risk due to the ABID policy. For this patient, while there was less than the expected increment to an antigen‐positive unit, there was no clinical or laboratory evidence of an aHTR. During this same time, 6095 ABIDs were performed, at a cost of approximately $1.29 million, and 72,665 red cell transfusions occurred. Conclusion With an ABID every 30 days, only one patient, over 4.5 years, was put at potential risk for hemolysis from one transfusion (0.001% of the total units transfused during the time period). While antibody detection may be delayed, performing ABIDs every 30 days saves money and medical laboratory scientist time and should be balanced against potential patient harm.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.