Gallbladder mucocele (GBM) is a common extra-hepatic biliary syndrome in dogs with death rates ranging from 7-45%. Therefore, the aim of this study was to identify the association of survival with variables that could be utilized to improve clinical decisions. A total of 1194 dogs with a gross and histopathological diagnosis of GBM were included from 41 veterinary referral hospitals in this retrospective study. Dogs with GBM that demonstrated abnormal clinical signs had significantly greater odds of death than subclinical dogs in a univariable analysis (OR, 4.2; 95% CI, 2.14-8.23; P<0.001). The multivariable model indicated that categorical variables including owner recognition of
Objectives Glucose monitoring is an integral part of diabetes management. Interstitial glucose monitoring systems are increasingly commonly being used for this purpose in dogs and cats, including the use of a flash glucose monitoring system (FGMS). The aim of this study was to describe the incidence and nature of complications associated with the use of an FGMS in diabetic cats. Methods The medical records of all cats that had placement of a 14-day FGMS during a 1-year period were retrospectively reviewed. Data retrieved included the number of days the sensor remained attached and functional, location of sensor placement and complications associated with the sensor. Complications were defined as early sensor detachment, sensor failure prior to the end of the 14-day monitoring period and dermatologic changes at the sensor site. Descriptive statistics were used to characterize the data. Results Twenty cats had a total of 33 FGMSs placed. The majority (30/33 [91%]) of sensors were placed over the dorsolateral aspect of the thorax just caudal to the scapula. Twenty (61%) FGMSs remained attached and functional for the full 14 days. The overall incidence of complications associated with FGMS use was 10/33 (30%). The most frequent complication was early sensor detachment (n = 5/33 [15%]). Mild dermatologic changes (erythema, crusts) were noted with 4/33 (12%) FGMSs. More serious complications (skin erosions, abscess formation) were noted with 2/33 (6%) FGMSs. Conclusions and relevance The use of the FGMS is relatively safe in cats, although there are potential complications that owners should be made aware of.
Objectives Liver biopsy is necessary for a diagnosis of liver disease; however, post-biopsy bleeding is a concern. The aim of this study was to describe the extent of bleeding and the occurrence of complications after percutaneous ultrasound-guided liver biopsy (PUGLB) in cats. Methods The medical records of 30 cats that had a PUGLB were retrospectively reviewed. Using human guidelines, bleeding was classified as minor or major when the absolute change in packed cell volume (ΔPCV) was >0 and <-6% or ≥-6%, respectively. Complications were defined as physiologic compromise necessitating an intervention, or death. The relationship between ΔPCV and the occurrence of complications and the signalment, initial PCV, coagulation parameters, serum liver enzymes and bilirubin, number of biopsies, histological diagnosis, ultrasound findings, radiologist experience, concurrent procedures and vitamin K administration were assessed using Fisher's exact test, ANOVA and Pearson's correlation coefficient, with a P value <0.05 considered significant. Results All cats had a decrease in PCV after biopsy. The mean ΔPCV was -6.9% ± 4.1%. Minor and major bleeding occurred in 13/30 (43.3%) and 17/30 (56.7%) cats, respectively, and non-lethal bleeding complications in 5/30 (16.7%). Cats with complications had a lower pre-biopsy PCV ( P <0.003). Major bleeding was more likely with a diagnosis of hepatic lipidosis ( P = 0.03). There was no correlation between ΔPCV or complications and signalment, coagulation parameters, serum parameters, number of biopsies, ultrasound findings, radiologist experience, concurrent procedures and vitamin K administration. Conclusions and relevance A PUGLB is a relatively safe procedure in cats, although many cats have a subclinical decrease in PCV. As conventional coagulation tests did not predict complications or the magnitude of ΔPCV, there is a need for more sensitive indicators of bleeding risk in cats undergoing PUGLB.
Background: Liver biopsy is often necessary to obtain a diagnosis in dogs with hepatobiliary disease. Hemorrhage after biopsy is a concern. Objective: To describe the extent of hemorrhage and incidence of complications after percutaneous ultrasound guided liver biopsy (PUGLB) in dogs and to examine risk factors for hemorrhage or complications. Animals: One hundred two client owned dogs with suspected hepatobiliary disease that underwent PUGLB. Methods: Medical records were retrospectively reviewed. Using human guidelines, major hemorrhage was defined as an absolute decrease in the PCV (ΔPCV) ≥ 6%. Complications were defined separately as clinically relevant physiologic compromise that necessitated intervention or death. The relationship between ΔPCV and the occurrence of complications and the initial PCV, coagulation variables, serum activity of liver-derived enzymes, serum bilirubin concentration, number of biopsies, biopsy needle gauge, radiologist experience, histological diagnosis, and ultrasound variables were compared. Results: Before PUGLB, most aberrations in coagulation variables were mild. After biopsy a decrease in PCV occurred in 87/102 (85.3%) dogs. The mean ΔPCV was −7.2% ± 4.5%. Major hemorrhage occurred in 43/102 (42.2%) dogs and complications in 2/102 (1.9%). ΔPCV was significantly positively correlated with PCV before biopsy (r = .47, P = .004). There was no correlation between ΔPCV or complications with any of the variables examined. Conclusion and Clinical Importance: Percutaneous ultrasound guided liver biopsy in the population of dogs in the current study, with normal or mild abnormalities in coagulation, results in a high incidence of clinically silent, major hemorrhage (42.5%), but few complications (1.9%).
Background: Gallbladder mucocele (GBM) is a common biliary disorder in dogs.Limited information is available on the coagulation status of dogs with GBM.Hypothesis/Objectives: To determine patterns of coagulation alterations in dogs with GBM and correlate them with clinicopathologic abnormalities and ultrasonographic findings of disease severity.Animals: Twenty-three dogs with GBM identified on ultrasound examination were prospectively enrolled.Methods: At the time of GBM identification, blood and urine were collected for CBC, serum biochemical panel, urinalysis, prothrombin time, activated partial thromboplastin time (aPTT), factor VIII, protein C (PC), von Willebrand's factor (vWF), antithrombin activity, fibrinogen, D-dimers, and thromboelastrography (TEG). Gallbladder mucoceles were classified into ultrasound types 1 to 5. Medical records were reviewed for clinical presentation, underlying conditions and to determine if systemic inflammatory response syndrome (SIRS) was present.Results: Based on TEG parameters, maximal amplitude, and G, 19/23 (83%) of dogs with GBM had evaluations consistent with hypercoagulability. On plasma-based coagulation testing, dogs with GBM had increased total PC activity (20/23, 87%), fibrinogen (9/23, 39%), platelet count (9/23, 39%), and D-dimers (6/15, 40%) as well as prolongations in aPTT (9/22, 41%) and low vWF activity (5/21, 24%). No correlation was found between TEG G value and any coagulation or clinical pathology variables, ultrasound stage of GBM or disease severity as assessed by the presence of SIRS.Conclusions and Clinical Importance: Dogs with ultrasonographically identified GBM have changes in whole blood kaolin-activated TEG supporting a hypercoagulable state although traditional plasma-based coagulation testing suggests that a complex state of hemostasis exists.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.