Background Five percent of adult patients undergoing noncardiac inpatient surgery experience a major pulmonary complication. The authors hypothesized that the choice of neuromuscular blockade reversal (neostigmine vs. sugammadex) may be associated with a lower incidence of major pulmonary complications. Methods Twelve U.S. Multicenter Perioperative Outcomes Group hospitals were included in a multicenter observational matched-cohort study of surgical cases between January 2014 and August 2018. Adult patients undergoing elective inpatient noncardiac surgical procedures with general anesthesia and endotracheal intubation receiving a nondepolarizing neuromuscular blockade agent and reversal were included. Exact matching criteria included institution, sex, age, comorbidities, obesity, surgical procedure type, and neuromuscular blockade agent (rocuronium vs. vecuronium). Other preoperative and intraoperative factors were compared and adjusted in the case of residual imbalance. The composite primary outcome was major postoperative pulmonary complications, defined as pneumonia, respiratory failure, or other pulmonary complications (including pneumonitis; pulmonary congestion; iatrogenic pulmonary embolism, infarction, or pneumothorax). Secondary outcomes focused on the components of pneumonia and respiratory failure. Results Of 30,026 patients receiving sugammadex, 22,856 were matched to 22,856 patients receiving neostigmine. Out of 45,712 patients studied, 1,892 (4.1%) were diagnosed with the composite primary outcome (3.5% sugammadex vs. 4.8% neostigmine). A total of 796 (1.7%) patients had pneumonia (1.3% vs. 2.2%), and 582 (1.3%) respiratory failure (0.8% vs. 1.7%). In multivariable analysis, sugammadex administration was associated with a 30% reduced risk of pulmonary complications (adjusted odds ratio, 0.70; 95% CI, 0.63 to 0.77), 47% reduced risk of pneumonia (adjusted odds ratio, 0.53; 95% CI, 0.44 to 0.62), and 55% reduced risk of respiratory failure (adjusted odds ratio, 0.45; 95% CI, 0.37 to 0.56), compared to neostigmine. Conclusions Among a generalizable cohort of adult patients undergoing inpatient surgery at U.S. hospitals, the use of sugammadex was associated with a clinically and statistically significant lower incidence of major pulmonary complications. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New
Use of the electronic health record (EHR) has become a routine part of perioperative care in the United States. Secondary use of EHR data includes research, quality, and educational initiatives. Fundamental to secondary use is a framework to ensure fidelity, transparency, and completeness of the source data. In developing this framework, competing priorities must be considered as to which data sources are used and how data are organized and incorporated into a useable format. In assembling perioperative data from diverse institutions across the United States and Europe, the Multicenter Perioperative Outcomes Group (MPOG) has developed methods to support such a framework. This special article outlines how MPOG has approached considerations of data structure, validation, and accessibility to support multicenter integration of perioperative EHRs. In this multicenter practice registry, MPOG has developed processes to extract data from the perioperative EHR; transform data into a standardized format; and validate, deidentify, and transfer data to a secure central Coordinating Center database. Participating institutions may obtain access to this central database, governed by quality and research committees, to inform clinical practice and contribute to the scientific and clinical communities. Through a rigorous and standardized approach to ensure data integrity, MPOG enables data to be usable for quality improvement and advancing scientific knowledge. As of March 2019, our collaboration of 46 hospitals has accrued 10.7 million anesthesia records with associated perioperative EHR data across heterogeneous vendors. Facilitated by MPOG, each site retains access to a local repository containing all site-specific perioperative data, distinct from source EHRs and readily available for local research, quality, and educational initiatives. Through committee approval processes, investigators at participating sites may additionally access multicenter data for similar initiatives. Emerging from this work are 4 considerations that our group has prioritized to improve data quality: (1) data should be available at the local level before Coordinating Center transfer; (2) data should be rigorously validated against standardized metrics before use; (3) data should be curated into computable phenotypes that are easily accessible; and (4) data should be collected for both research and quality improvement purposes because these complementary goals bolster the strength of each endeavor.
Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New Background Compared with historic ventilation strategies, modern lung-protective ventilation includes lower tidal volumes (VT), lower driving pressures, and application of positive end-expiratory pressure (PEEP). The contributions of each component to an overall intraoperative protective ventilation strategy aimed at reducing postoperative pulmonary complications have neither been adequately resolved, nor comprehensively evaluated within an adult cardiac surgical population. The authors hypothesized that a bundled intraoperative protective ventilation strategy was independently associated with decreased odds of pulmonary complications after cardiac surgery. Methods In this observational cohort study, the authors reviewed nonemergent cardiac surgical procedures using cardiopulmonary bypass at a tertiary care academic medical center from 2006 to 2017. The authors tested associations between bundled or component intraoperative protective ventilation strategies (VT below 8 ml/kg ideal body weight, modified driving pressure [peak inspiratory pressure − PEEP] below 16 cm H2O, and PEEP greater than or equal to 5 cm H2O) and postoperative outcomes, adjusting for previously identified risk factors. The primary outcome was a composite pulmonary complication; secondary outcomes included individual pulmonary complications, postoperative mortality, as well as durations of mechanical ventilation, intensive care unit stay, and hospital stay. Results Among 4,694 cases reviewed, 513 (10.9%) experienced pulmonary complications. After adjustment, an intraoperative lung-protective ventilation bundle was associated with decreased pulmonary complications (adjusted odds ratio, 0.56; 95% CI, 0.42–0.75). Via a sensitivity analysis, modified driving pressure below 16 cm H2O was independently associated with decreased pulmonary complications (adjusted odds ratio, 0.51; 95% CI, 0.39–0.66), but VT below 8 ml/kg and PEEP greater than or equal to 5 cm H2O were not. Conclusions The authors identified an intraoperative lung-protective ventilation bundle as independently associated with reduced pulmonary complications after cardiac surgery. The findings offer insight into components of protective ventilation associated with adverse outcomes and may serve as targets for future prospective interventional studies investigating the impact of specific protective ventilation strategies on postoperative outcomes after cardiac surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.