The determination of daily concentrations of atmospheric pollen is important in the medical and biological fields. Obtaining pollen concentrations is a complex and time-consuming task for specialized personnel. The automatic location of pollen grains is a handicap due to the high complexity of the images to be processed, with polymorphic and clumped pollen grains, dust, or debris. The purpose of this study is to analyze the feasibility of implementing a reliable pollen grain detection system based on a convolutional neural network architecture, which will be used later as a critical part of an automated pollen concentration estimation system. We used a training set of 251 videos to train our system. As the videos record the process of focusing the samples, this system makes use of the 3D information presented by several focal planes. Besides, a separate set of 135 videos (containing 1234 pollen grains of 11 pollen types) was used to evaluate detection performance. The results are promising in detection (98.54% of recall and 99.75% of precision) and location accuracy (0.89 IoU as the average value). These results suggest that this technique can provide a reliable basis for the development of an automated pollen counting system.
In this work, we present a complete hardware development and current consumption study of a portable electronic nose designed for the Internet-of-Things (IoT). Thanks to the technique of measuring in the initial action period, it can be reliably powered with a moderate-sized battery. The system is built around the well-known SoC (System on Chip) ESP8266EX, using low-cost electronics and standard sensors from Figaro’s TGS26xx series. This SoC, in addition to a powerful microcontroller, provides Wi-Fi connectivity, making it very suitable for IoT applications. The system also includes a precision analog-to-digital converter for the measurements and a charging module for the lithium battery. During its operation, the designed software takes measurements periodically, and keeps the microcontroller in deep-sleep state most of the time, storing several measurements before uploading them to the cloud. In the experiments and tests carried out, we have focused our work on the measurement and optimization of current consumption, with the aim of extending the battery life. The results show that taking measurements every 4 min and uploading data every five measurements, the battery of 750 mAh needs to be charged approximately once a month. Despite the fact that we have used a specific model of gas sensor, this methodology is quite generic and could be extended to other sensors with lower consumption, increasing very significantly the duration of the battery.
The presence of clustered microcalcifications is one of the earliest signs in breast cancer detection. Although there exist many studies broaching this problem, most of them are nonreproducible due to the use of proprietary image datasets. We use a known subset of the currently largest publicly available mammography database, the Digital Database for Screening Mammography (DDSM), to develop a computer-aided detection system that outperforms the
current reproducible studies on the same mammogram set. This proposal is mainly based on the use of extracted image features obtained by independent component analysis, but we also study the inclusion of the patient's age as a nonimage feature which requires no human expertise. Our system achieves an average of 2.55 false positives per image at a sensitivity of 81.8% and 4.45 at a sensitivity of 91.8% in diagnosing the BCRP_CALC_1 subset of DDSM.
One of the parameters that are usually stored for mammograms is the BI-RADS density, which gives an idea of the breast tissue composition. In this work, we study the effect of BI-RADS density in our ongoing project for developing an image-based CAD system to detect masses in mammograms. This system consists of two stages. First, a blind feature extraction is performed for regions of interest (ROIs), using Independent Component Analysis (ICA). Next, in the second stage, those features form the input vectors to a classifier, neural network, or SVM classifier. To train and test our system, the Digital Database for Screening Mammography (DDSM) was used. The results obtained show that the maximum variation in the performance of our system considering only prototypes obtained from mammograms with a concrete value of density (both for training and test) is about 7%, yielding the best values for density equal to 1, and the worst for density equal to 4, for both classifiers. Finally, with the overall results (i.e., using prototypes from mammograms with all the possible values of densities), we obtained a difference in performance that is only 2% lower than the maximum, also for both classifiers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.