The purpose of this study was to test the superiority of a soft tissue‐based setup using cone‐beam computed tomography (CBCT) to a bony structure‐based setup using the ExacTrac system in intensity‐modulated radiotherapy (IMRT) for prostate cancer. We studied 20 patients with localized prostate cancer who received IMRT between November 2010 and February 2012. After the initial setup, the pelvic bony structure‐based setup and ExacTrac system were applied. After that, CBCT and a soft tissue‐based setup were used. A shift in the isocenter between the ExacTrac‐based and CBCT‐based setup was recorded in the anterior–posterior (AP), superior–inferior (SI), and left–right (LR) axes. The shift was considered an interfractional prostate shift. Post‐treatment CBCT was also taken once a week to measure the intrafractional prostate shift, based on the coordinates of the isocenter between pre‐ and post‐treatment CBCT. The planning target volume (PTV) margins were determined using van Herk's method. We measured the elapsed time required for soft tissue matching and the entire treatment time using CBCT. The means±standard deviationfalse(SDfalse) of the inter‐ and intrafractional shifts were 0.9±2.8 mm and −0.3±1.4 mm in the AP, 0.9±2.2 mm and −0.1±1.2 mm in the SI, and 0.1±0.7 mm and −0.1±0.7 mm in the LR directions. The PTV margins in the cases of bony structure‐based and soft tissue‐based setups were 7.3 mm and 2.7 mm in the AP, 5.8 mm and 2.3 mm in the SI, and 1.9 mm and 1.2 mm in the LR directions. Even though the median elapsed time using CBCT was expanded in 5.9 min, the PTV margins were significantly reduced. We found the calculated PTV margins in the soft tissue‐based setup using CBCT were small, and this arrangement was superior to the bony structure‐based setup in prostate IMRT.PACS numbers: 87.19.ru, 87.55.T‐
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.