Objectives
The aim of this study was to evaluate the accuracy of complete‐arch digital impressions for fabrication of an implant‐supported prosthesis in the edentulous maxilla using an auxiliary geometry part.
Materials and methods
A replica of the upper jaw of an edentulous patient with four scannable impression copings was fabricated in stainless steel. This model was scanned with an industrial non‐contact 3D structured blue light 3D scanner, and the measurements of three reference distances were established as reference values. Subsequently, the model was scanned in two different scenarios (with or without an auxiliary geometry part put in place and fixed to the model) using three intraoral scanners. Measurements were taken with 3D inspection software, and a digital impression of the complete arch was built with mesh processing software by combining 2 STL files obtained with an intraoral scanner.
Results
All measurements with the auxiliary geometry part gave significantly more accurate results (p < .05). Trueness improved in the three reference distances, reaching values of 8 ± 6 µm at D12 reference distance, 20 ± 11 µm at D13 and 35 ± 22 µm at D14. Precision also improved significantly with the use of the auxiliary geometry part placed on the model (p < .05). The best precision results at reference distances D13 and D14 were obtained with the True Definition Scanner.
Conclusions
The proposed methodology significantly improves the accuracy of complete‐arch digital impressions in edentulous patients obtained in vitro, regardless of which scanner is used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.