For the diagnosis of disease, the ability to quantitatively detect trace amounts of the causal proteins from bacteria/viruses as biomarkers in patient specimens is highly desirable. Here we introduce a simple, rapid, and colorimetric assay as a de novo, ultrasensitive detection method. This ultrasensitive assay consists of a sandwich enzyme-linked immunosorbent assay (ELISA) and thionicotinamide-adenine dinucleotide (thio-NAD) cycling, forming an ultrasensitive ELISA, in which the signal substrate (i.e., thio-NADH) accumulates in a triangular manner, and the accumulated thio-NADH is measured at its maximum absorption wavelength of 405 nm. We have successfully achieved a limit of detection of ca. 10−18 moles/assay for a target protein. As an example of infectious disease detection, HIV-1 p24 could be measured at 0.0065 IU/assay (i.e., 10−18 moles/assay), and as a marker for a lifestyle-related disease, adiponectin could be detected at 2.3 × 10−19 moles/assay. In particular, despite the long-held belief that the trace amounts of adiponectin in urine can only be detected using a radioisotope, our ultrasensitive ELISA was able to detect urinary adiponectin. This method is highly versatile because simply changing the antibody enables the detection of various proteins. This assay system requires only the measurement of absorbance, thus it requires equipment that is easily obtained by medical facilities, which facilitates diagnosis in hospitals and clinics. Moreover, we describe an expansion of our ultrasensitive ELISA to a non-amplification nucleic acid detection method for nucleic acids using hybridization. These de novo methods will enable simple, rapid, and accurate diagnosis.
ObjectiveThe chronic kidney disease (CKD) is widely diagnosed on the basis of albuminuria and the glomerular filtration rate. A more precise diagnosis of CKD, however, requires the assessment of other factors. Urinary adiponectin recently attracted attention for CKD assessment, but evaluation is difficult due to the very low concentration of urinary adiponectin in normal subjects.Research design and methodsWe developed an ultrasensitive ELISA coupled with thionicotinamide-adenine dinucleotide cycling to detect trace amounts of proteins, which allows us to measure urinary adiponectin at the subattomole level. We measured urinary adiponectin levels in 59 patients with diabetes mellitus (DM) and 24 subjects without DM (normal) to test our hypothesis that urinary adiponectin levels increase with progression of CKD due to DM.ResultsThe urinary adiponectin levels were 14.88±3.16 (ng/mg creatinine, mean±SEM) for patients with DM, and 3.06±0.33 (ng/mg creatinine) for normal subjects. The threshold between them was 4.0 ng/mg creatinine. The urinary adiponectin levels increased with an increase in the CKD risk. Furthermore, urinary adiponectin mainly formed a medium-molecular weight multimer (a hexamer) in patients with DM, whereas it formed only a low-molecular weight multimer (a trimer) in normal subjects. That is, the increase in urinary adiponectin in patients with DM led to the emergence of a medium-molecular weight form in urine.ConclusionsOur new assay showed that urinary adiponectin could be a new diagnostic index for CKD. This assay is a non-invasive test using only urine, thus reducing the patient burden.
For the diagnosis of disease, the ability to quantitatively detect trace amounts of the causal proteins from bacteria/viruses as biomarkers in patient specimens is highly desirable. Here we introduce a simple, rapid, and colorimetric assay as a de novo, ultrasensitive detection method. This ultrasensitive assay consists of sandwich enzyme-linked immunosorbent assay (ELISA) and thionicotinamide-adenine dinucleotide (thio-NAD) cycling, forming an ultrasensitive ELISA, in which the signal substrate (i.e., thio-NADH) accumulates in a triangular manner, and the accumulated thio-NADH is measured at its maximum absorption wavelength of 400 nm. We have successfully achieved a limit of detection of ca. 10–18 moles/assay for a target protein. As an example of infectious disease detection, HIV-1 p24 could be measured at 0.0065 IU/assay (i.e., 10−18 moles/assay), and as a marker for a lifestyle-related disease, adiponectin could be detected at 2.3 × 10−19 moles/assay. In particular, despite the long-held belief that the trace amounts of adiponectin in urine can only be detected using a radioisotope, our ultrasensitive ELISA was able to detect urinary adiponectin. This method is highly versatile, because simply changing the antibody enables the detection of various proteins. This assay system requires only the measurement of absorbance, thus it requires equipment that is easily obtained by medical facilities, which facilitates diagnosis in hospitals and clinics. Moreover, we describe an expansion of our ultrasensitive ELISA to a non-amplification nucleic acid detection method for nucleic acids using hybridization. These de novo methods will enable simple, rapid, and accurate diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.