We report the results of experiments where a quantitative analysis of the behavior of ablation modulations in X-pinches (including wavelength and contrast between streams) was carried out as a function of distance from the cross-point, and consequently, as a function of the global to local magnetic field ratio. Experiments were performed using two tungsten wires of 10 µm diameter in an X-pinch configuration on a pulsed power generator capable of producing an 80 kA current over a 50 ns rise time. We compare these findings directly to three-dimensional magneto-hydrodynamic (MHD) simulations using the MHD resistive code GORGON. Here, we demonstrate a dependence between the magnetic field ratio and ablation properties, suggesting a transition to a classical m = 0 instability far from the cross-point. Additionally, we examine the ablation properties of similar Z number nickel and copper wire X-pinches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.