The regional key comparison of absolute gravimeters, EURAMET.M.G-K3 and the simultaneously organized additional comparison, was held in Germany at the Geodetic Observatory Wettzell of the German Federal Agency for Cartography and Geodesy in the spring of 2018.
Here we present the list of the participants who actually performed measurements during the comparison, the data submitted by the operators as well as the results of the determination of the gravity as a function of height at the comparison sites. The measurement strategy is briefly discussed and the results of the data harmonization is documented. Finally, the results of the constrained least squares adjustment are presented including the degrees of equivalence of each gravimeter and the key comparison reference values.
Main text
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
The systematic effects of absolute gravimeters have to be investigated to fully utilize their capabilities in metrology and geosciences. In Křen et al (2016 Metrologia 53 27-40) we found that for an FG5 gravimeter, even a few meter long coaxial cable used for transmission of fringe signal causes systematic features in residuals and errors at the level of 1-2 µGal. In this paper, we present experimental results and appropriate models to explain the effects that were found to be caused by impedance mismatches of electronic components and dispersion effects in coaxial cables of gravimeters. The experimental results have been obtained for analogue and transistor-transistor logic (TTL) compatible signals in the FG5-215 gravimeter and for a TTL signal in the FG5X-251 gravimeter. We found that dispersion and impedance mismatch effects are similar for both gravimeters. Furthermore, we describe a model of the dispersion that allows an evaluation of the effect/correction for a given range of the free-fall and thus it is also applicable to other gravimeters. The effect of impedance mismatch for the analogue fringe signal is modelled as an effect of the reflected electronic signal on the evaluation of zero-crossings. The applicability of this model for TTL signal is also discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.