In this study, the heat transfer and friction characteristics of nonsymmetric slit-finned heat exchangers are experimentally investigated. Louver-finned heat exchangers are also tested for comparison purpose. The effect of fin pitch on j and f factors is negligible. Considering the small variation of the fin pitch (from 1.3 mm to 1.5 mm), the foregoing argument should hold true for the present samples. Louver fin samples yield higher j and f factors than slit fin samples. Both j and f factors increase as the number of tube rows decreases. The row effect is true for both slit and louver fin samples. For one-row configuration, j/f ratios of louver fin samples are larger than those of slit fin samples. The trend is, however, reversed for three-row configuration. Data are compared with available correlations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.