Percutaneous vertebroplasty (VP) and kyphoplasty (KP) are well-established minimally invasive surgical procedures for the treatment of osteoporotic vertebral compression fractures (OVCF). However, some drawbacks have been reported regarding these procedures, including height loss, cement leakage, and loss of the restored height after balloon deflation. We performed a novel VP technique to minimize these limitations of conventional procedures. This study aimed to compare radiological and clinical outcomes of our method using a larger-diameter needle versus conventional VP (using a smaller needle) for thoracolumbar OVCF.
From April 2016 to May 2017, 107 consecutive patients diagnosed with thoracolumbar OVCF were enrolled. Patients were divided into two groups: group 1 underwent conventional VP, i.e., using a smaller diameter needle, and group 2 underwent VP through a modified method with a larger-diameter needle. For radiological evaluation, parameters related to anterior vertebral height (AVH) and segmental angle were assessed using plain standing radiographs, and patient-reported outcomes were evaluated using the visual analog scale. Cement injection amount and leakage pattern were also analyzed. Group 2 showed a larger anterior vertebral height change than group 1 immediately postoperatively and one year postoperatively. The 1-year postoperatively-AVH maintained better in group 2 than in group 1. Group 2 showed more significant improvement of segmental angle immediately postoperatively than group 1 (3.15° in group 1 vs 9.36° in group 2). IYPo-visual analog scale significantly improved in both groups, with greater improvement in group 2 (3.69 in group 1 vs 5.63 in group 2). A substantially larger amount of cement was injected, with a lower leakage rate in group 2 than in group 1.
A novel VP technique using a larger-diameter needle showed superior radiological and clinical outcomes than conventional VP. Therefore, it can be considered a useful treatment option for OVCF.
Backgroud
Although the scallop sign is considered the most important risk factor for extensor tendon ruptures (ETRs) in patients with osteoarthritis of the distal radioulnar joint (DRUJ), previous reports provide a limited understanding of the changes at DRUJ, as risk factors were examined in plain radiographs of the wrist. The aim of this study was to assess the changes of DRUJ using axial images of computed tomography (CT) in patients with DRUJ osteoarthritis and associated ETRs and to evaluate the relationship between the changes of DRUJ and ETRs.
Methods
Twelve patients with ETRs due to osteoarthritis of the DRUJ were enrolled. The changes of DRUJ were examined on axial images of CT and the following 8 parameters were measured: width of radius, anteroposterior (AP) length of radius, width of sigmoid notch (SN), AP length of SN, AP length of ulnar head, subluxation length of ulnar head, dorsal inclination of SN, and distance from Lister's tubercle to SN. Radiological parameters of the DRUJ were measured in 60 control wrists without trauma or osteoarthritis, and the patient and control groups were statistically compared.
Results
Statistically significant differences were observed between the patient and control groups in all the radiological parameters except for the AP length of SN and AP length of ulnar head. The width of radius, AP length of radius, width of SN, subluxation length of ulnar head, and dorsal inclination of SN were greater and the distance from Lister's tubercle to SN was smaller in the patient group than in the control group. The width of SN, dorsal inclination of SN, and distance from Lister's tubercle to SN were statistically significant risk factors among the 8 parameters.
Conclusions
ETRs due to osteoarthritis of the DRUJ was related to the changes of DRUJ, especially the changes around SN of the distal radius. In addition to the existing risk factors, a decreased distance from Lister's tubercle to SN and increased dorsal inclination of SN were identified as new risk factors. Axial images of CT were effective to evaluate degenerative changes at the DRUJ.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.