This paper presents a circulating tumor cell (CTC) microseparator for isolation of CTCs from human peripheral blood using immunomagnetic nanobeads with bound antiepithelial cell adhesive molecule (EpCAM) antibodies that specifically bind to epithelial cancer cells. The isolation is performed through lateral magnetophoresis, which is induced by high-gradient magnetic separation technology, involving a ferromagnetic wire array inlaid in the bottom substrate of a microchannel. Experimental results showed that the CTC microseparator isolates about 90% of spiked CTCs in human peripheral blood at a flow rate of up to 5 mL/h and purifies to approximately 97%. The overall isolation procedure was completed within 15 min for 200 μL of peripheral blood. CTCs from peripheral blood of patients with breast and lung cancers were isolated with the CTC microseparator, and the results were compared with those of healthy donors. Using a fluorescence-based viability assay, the viability of CTCs isolated from peripheral blood of patients with cancer was observed. In addition, the usefulness of the CTC microseparator for subsequent genetic assay was confirmed by reverse-transcriptase polymerase chain reaction (RT-PCR) amplification of cancer-specific genes using CTCs isolated from patients with cancer.
PET detectors with depth-of-interaction (DOI) encoding capability allow high spatial resolution and high sensitivity to be achieved simultaneously. To obtain DOI information from a mono-layer array of scintillation crystals using a single-ended readout, the authors devised a method based on light spreading within a crystal array and performed Monte Carlo simulations with individual scintillation photon tracking to prove the concept. A scintillation crystal array model was constructed using a grid method. Conventional grids are constructed using comb-shaped reflector strips with rectangular teeth to isolate scintillation crystals optically. However, the authors propose the use of triangularly shaped teeth, such that scintillation photons spread only in the x-direction in the upper halves of crystals and in the y-direction in lower halves. DOI positions can be estimated by considering the extent of two-dimensional light dispersion, which can be determined from the multiple anode outputs of a position-sensitive PMT placed under the crystal array. In the main simulation, a crystal block consisting of a 29x29 array of 1.5 mmx1.5 mmx20 mm crystals and a multi-anode PMT with 16x16 pixels were used. The effects of crystal size and non-uniform PMT output gain were also explored by simulation. The DOI resolution estimated for 1.5x1.5x20 mm3 crystals was 2.16 mm on average. Although the flood map was depth dependent, each crystal was well identified at all depths when a corner of the crystal array was irradiated with 511 keV gamma rays (peak-to-valley ratio approximately 9:1). DOI resolution was better than 3 mm up to a crystal length of 28 mm with a 1.5x1.5 mm2 or 2.0x2.0 mm2 crystal surface area. The devised light-sharing method allowed excellent DOI resolutions to be obtained without the use of dual-ended readout or multiple crystal arrays.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.