The indications and techniques for the treatment of intracranial lesions continue to evolve with the advent of novel technologies. The Gamma Knife Icon™ (GK Icon™) is the most recent model available from Elekta, providing a frameless solution for stereotactic radiosurgery. At our institution, 382 patients with 3,213 separate intracranial lesions have been treated with frameless stereotactic radiotherapy using the GK Icon. The wide range of diagnoses include brain metastases, meningiomas, arteriovenous malformations, acoustic neuromas, pituitary adenomas, and several other histologies. The ability to perform both frame and frameless treatments on the GK Icon has significantly increased our daily volume by almost 50% on a single machine. Although the frameless approach allows one to take advantage of the precision in radiosurgery, the intricacies regarding treatment with this frameless system are not well established. Our initial experience will help to serve as a guide to those wishing to implement this novel technology in their practice.
Deep inspiration breath-hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left-sided breast cancer.We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT).
Materials and Methods:We examined intra-and inter-fraction positional variation of the left lung. Eight left-sided breast cancer patients were monitored with electronic portal imaging during breath-hold (BH) at every fraction. For each patient, half of the fractions were treated using ABC and the other half with VRT, with an equal amount starting with either ABC or VRT. The lung in each portal image was delineated, and the variation of its area was evaluated. Intrafraction stability was evaluated as the mean coefficient of variation (CV) of the lung area for the supraclavicular (SCV) and left lateral (LLat) field over the course of treatment. Reproducibility was the CV for the first image of each fraction. Daily session time and total imaging monitor units (MU) used in patient positioning were recorded. Results: The mean intrafraction stability across all patients for the LLat field was 1.3 ± 0.7% and 1.5 ± 0.9% for VRT and ABC, respectively. Similarly, this was 1.5 ± 0.7% and 1.6 ± 0.8% for VRT and ABC, respectively, for the SCV field. The mean interfraction reproducibility for the LLat field was 11.0 ± 3.4% and 14.9 ± 6.0% for VRT and ABC, respectively. Similarly, this was 13.0 ± 2.5% and 14.8 ± 9% for VRT and ABC, respectively, for the SCV. No difference was observed in the number of verification images required for either technique. Conclusions: The stability and reproducibility were found to be comparable between ABC and VRT. ABC can have larger interfractional variation with less feedback to the treating therapist compared to VRT as shown in the increase in geometric misses at the matchline.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.