As fabs transition from 200 to 300mm wafers with shrinking design rules, the risk and cost associated with overlay excursions become more severe. This significantly impacts the overall litho-cell efficiency. Effective detection, identification, and reduction of overlay excursions are essential for realizing the productivity and cost benefits of the technology shifts. We have developed a comprehensive overlay excursion management method that encompasses baseline variation analysis, statistical separation and characterization of excursion signatures and their frequencies, as well as selection of sampling plans and control methods that minimize material at risk due to excursion. A novel baseline variance estimation method is developed that takes into account the spatial signature and temporal behavior of the litho-cell overlay correction mechanisms. Spatial and temporal excursion signatures are identified and incorporated in a cost model that estimates the material at risk in an excursion cycle. The material at risk associated with various sampling plans, control charts, and cycle times is assessed considering various lot disposition and routing decisions. These results are then used in determining an optimal sampling and control strategy for effective excursion management. In this paper, we describe and demonstrate the effectiveness of the methods using actual 300mm fab overlay data from several critical layers. With a thorough assessment of the actual baseline and excursion distributions, we quantify the amount of wafer-to-wafer and within-wafer sampling necessary for detecting excursions with minimal material at risk. We also evaluate the impact of shorter cycle time and faster response to excursion, which is made possible through automation and alternative metrology configurations.
The lens heating focus correction on stepper is not good enough on the current procedure provided by ASML ® . It can only solve the wafer to wafer CD variation but not within wafer. It caused the CD at a wafer top and bottom is different. This is because there is no correction for lens heating if no special trigger while exposing within one wafer.In small UDOF process like 0.3 µm poly gate, CD is very sensitive to the focus drift. The within wafer lens heating effect causes the focus drift and worsen focus control. Even the lens heating correction factor has been optimized, it still suffers the poor within wafer CD uniformity issue.One tricky method, using of multi-image setting, to trigger the lens heating correction is proposed to improve the within wafer CD uniformity in this report. The poly gate CD uniformity (3 ) on 0.3 µm production were improved from 25nm to 15nm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.