Magnetic core loss is an important concern for power converters. As the switching frequency increases and converter size reduced, the core loss will have significant impact to the converter efficiency and temperature. Accurate evaluation is important for magnetic design and converter loss estimation. The classic two-winding method is limited to low frequencies (usually below 1 MHz) because it is sensitive to phase discrepancy. In this paper, a new method is proposed for high-frequency core loss measurement that utilizes capacitive cancellation, which is suitable for HF and VHF core loss measurement. The new method greatly reduces the sensitivity to phase discrepancy, which is the dominating error source in the conventional two-winding method. An experimental demonstration is performed at 10 MHz, and the possible errors are analyzed in detail. With the proposed method, the high-frequency core loss can be accurately measured.Index Terms-Core loss measurement, ferrite, high frequency, magnetic integration, magnetic loss.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.