Power cable condition diagnosis and deterioration location rely on signatures of aging characteristics which precede the final breakdown. The purpose of this study was to investigate how to diagnose and locate the aging and/or deterioration of power cables through the analysis of the impedance spectroscopy. The concepts of the reference frequency and characteristic frequency of cable impedance spectroscopy are defined for the first time. Based on the reference frequency, the optimal frequency range for analysis of impedance spectroscopy can be determined, whilst based on characteristic frequency, a set of criteria for assessing cable conditions are examined and established. The solution proposed in this paper has the advantage of being easier to implement than the previously reported “broadband” impedance spectroscopy methods, as it helps to reduce the frequency range for measurement instrumentations; the proposed method also does not need the measurements of the parameters of the cable being tested.
In order to explore the feasibility of impedance spectroscopy in the application of online diagnosis of aging and deterioration of medium voltage (MV) three-core cables, based on the theory of transmission line equation, an aging and deterioration model of the MV three-core cable has been established. The impedance spectroscopy of the cable head-end under healthy and different aging and degradation states has been simulated and analyzed. Further, the effects the extent of aging, local deterioration size and position, line length, load rate and other factors on the impedance spectroscopy have been studied. Based on the influence of the various factors on the impedance spectroscopy, a set of aging and deterioration diagnosis procedures and methods are proposed. The simulation results indicate that the impedance spectroscopies of healthy state and different aging and/or deterioration states have certain characteristics. These characteristics can be determined by specific criterion indicators such as the monotonous decrease of the value of the resonance peaks and the phase amplitudes, the value of the resonance peaks, and the eigen propagation frequency, etc. Therefore, impedance spectroscopy has broad application prospects for online diagnosis of aging and deterioration of MV three-core cable.INDEX TERMS Power cable, aging and deterioration, online diagnosis, impedance spectroscopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.