Extracranial carotid mural lesions (CML), caused by atherosclerosis or dissection, are frequently observed in acute internal carotid artery (ICA) occlusion, often requiring angioplasty or stenting. This study aimed to assess the diagnostic accuracy of computed tomography angiography (CTA) in differentiating extracranial CML from thromboembolic etiology in acute ICA occlusion in patients eligible for endovascular treatment. Two neuroradiologists retrospectively studied patients with apparent extracranial ICA occlusion on CTA. Patients were divided into two groups: thromboembolism and CML, based on findings from CTA and digital subtraction angiography (DSA). CTA sensitivity and specificity were calculated using DSA as the gold standard. Occlusive patterns and cervical segment widening were evaluated for atherosclerosis, dissection, and thromboembolism etiologies. CTA had a sensitivity of 84.91% (74.32–95.49%) and a specificity of 95.12% (87.31–100%) in detecting extracranial CML. Atherosclerosis was the most common cause, distinguishable with high accuracy using CTA (p < 0.001). No significant differences were found in occlusive patterns between dissection and thromboembolism (p = 0.568). Cervical segment widening was only observed in dissection cases due to mural hematoma. Conclusions: CTA accurately differentiates extracranial CML from thromboembolic etiology in acute ICA occlusion. The pattern of the occlusion and the artery widening help to establish the location and the etiology of the occlusion.
BACKGROUND
Endovascular embolization of wide-necked aneurysms can be challenging. The development of intrasaccular devices like the Contour has enabled us to approach these aneurysms effectively by reducing recanalization rates and eliminating the need for dual antiplatelet therapy, which is particularly beneficial in the case of ruptured aneurysms. Although complications from using these devices are rare, it is crucial to address them properly. In this case, the authors highlight how to manage artery thrombosis caused by device protrusion during aneurysm embolization.
OBSERVATIONS
This report describes a complication in a male patient with a ruptured anterior communicating artery wide-necked aneurysm. Following Contour-assisted coiling of the aneurysm, a realignment of the detachable apex of the device occluded the A2 segment of the right anterior cerebral artery. After the failure of intra-arterial and intravenous tirofiban infusion as well as mechanical thrombectomy, a self-expanding open-cell stent was deployed in the involved vessel, achieving successful reperfusion.
LESSONS
The Contour device has a detachable zone that can cause occlusion of the parent vessel after deployment. The use of a stent as a rescue maneuver may be useful if reperfusion of the vessel cannot be achieved through other methods such as aspiration or full-dose antiplatelet therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.