Aortic dissection (AD) is a vascular condition with high morbidity and mortality rates. Computational fluid dynamics (CFD) can provide insight into the progression of AD and aid clinical decisions; however, oversimplified modelling assumptions and high computational cost compromise the accuracy of the information and impede clinical translation. To overcome these limitations, a patient-specific CFD multi-scale approach coupled to Windkessel boundary conditions and accounting for wall compliance was developed and used to study a patient with AD. A new moving boundary algorithm was implemented to capture wall displacement and a rich in vivo clinical dataset was used to tune model parameters and for validation. Comparisons between in silico and in vivo data showed that this approach successfully captures flow and pressure waves for the patient-specific AD and is able to predict the pressure in the false lumen (FL), a critical variable for the clinical management of the condition. Results showed regions of low and oscillatory wall shear stress which, together with higher diastolic pressures predicted in the FL, may indicate risk of expansion. This study, at the interface of engineering and medicine, demonstrates a relatively simple and computationally efficient approach to account for arterial deformation and wave propagation phenomena in a three-dimensional model of AD, representing a step forward in the use of CFD as a potential tool for AD management and clinical support.
The optimal treatment of Type-B aortic dissection (AD) is still a subject of debate, with up to 50% of the cases developing late-term complications requiring invasive intervention. A better understanding of the patient-specific haemodynamic features of AD can provide useful insights on disease progression and support clinical management. In this work, a novel in vitro and in silico framework to perform personalised studies of AD, informed by non-invasive clinical data, is presented. A Type-B AD was investigated in silico using computational fluid dynamics (CFD) and in vitro by means of a state-of-the-art mock circulatory loop and particle image velocimetry (PIV). Both models not only reproduced the anatomical features of the patient, but also imposed physiologically-accurate and personalised boundary conditions. Experimental flow rate and pressure waveforms, as well as detailed velocity fields acquired via PIV, are extensively compared against numerical predictions at different locations in the aorta, showing excellent agreement. This work demonstrates how experimental and numerical tools can be developed in synergy to accurately reproduce patient-specific AD blood flow. The combined platform presented herein constitutes a powerful tool for advanced haemodynamic studies for a range of vascular conditions, allowing not only the validation of CFD models, but also clinical decision support, surgical planning as well as medical device innovation.
Aortic dissection (AD) is a complex and highly patient-specific vascular condition difficult to treat. Computational fluid dynamics (CFD) can aid the medical management of this pathology, yet its modelling and simulation are challenging. One aspect usually disregarded when modelling AD is the motion of the vessel wall, which has been shown to significantly impact simulation results. Fluid-structure interaction (FSI) methods are difficult to implement and are subject to assumptions regarding the mechanical properties of the vessel wall, which cannot be retrieved non-invasively. This paper presents a simplified 'moving-boundary method' (MBM) to account for the motion of the vessel wall in type-B AD CFD simulations, which can be tuned with non-invasive clinical images (e.g. 2D cine-MRI). The method is firstly validated against the 1D solution of flow through an elastic straight tube; it is then applied to a type-B AD case study and the results are compared to a state-of-the-art, full FSI simulation. Results show that the proposed method can capture the main effects due to the wall motion on the flow field: the average relative difference between flow and pressure waves obtained with the FSI and MBM simulations was less than 1.8% and 1.3%, respectively and the wall shear stress indices were found to have a similar distribution. Moreover, compared to FSI, MBM has the advantage to be less computationally expensive (requiring half of the time of an FSI simulation) and easier to implement, which are important requirements for clinical translation.
Patient-specific computational fluid-dynamics (CFD) can assist the clinical decision-making process for Type-B aortic dissection (AD) by providing detailed information on the complex intra-aortic haemodynamics. This study presents a new approach for the implementation of personalised CFD models using non-invasive, and oftentimes minimal, datasets commonly collected for AD monitoring. An innovative way to account for arterial compliance in rigid-wall simulations using a lumped capacitor is introduced, and a parameter estimation strategy for boundary conditions calibration is proposed. The approach was tested on three complex cases of AD, and the results were successfully compared against invasive blood pressure measurements. Haemodynamic results (e.g. intraluminal pressures, flow partition between the lumina, wall shear-stress based indices) provided information that could not be obtained using imaging alone, providing insight into the state of the disease. It was noted that small tears in the distal intimal flap induce disturbed flow in both lumina. Moreover, oscillatory pressures across the intimal flap were often observed in proximity to the tears in the abdominal region, which could indicate a risk of dynamic obstruction of the true lumen. This study shows how combining commonly available clinical data with computational modelling can be a powerful tool to enhance clinical understanding of AD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.