Purpose This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P <0.05. Results A statistically significant difference was found between the 3 intraoral scanners in trueness and precision ( P <0.05). Primescan AC showed the lowest trueness and precision values (36.8 µm and 42.0 µm; (39.4 µm and 51.2 µm; and 54.9 µm and 52.7 µm) followed by Trios 3 (38.9 µm and 53.5 µm; 49.9 µm and 59.1 µm; and 58.1 µm and 64.5 µm) and Planmeca Emerald (60.4 µm and 63.6 µm; 61.3 µm and 69.0 µm; and 70.8 µm and 74.3 µm) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.
Objective. This study aimed to evaluate the effect of nanoparticles, zirconium dioxide (ZrO2), titanium dioxide (TiO2), and silicon dioxide (SiO2), on flexural strength (FS), hardness, and wear resistance of light cured dental composite resin. Materials and Methods. 210 rectangular and disc-shaped composite resin specimens were fabricated with dimensions (25 × 2 × 2 ± 0.03 mm) and (6×4 ± 0.03 mm) for FS, hardness, and wear resistance, respectively (70/test). Specimens of each test were divided according to nanofillers into four groups, unmodified as control, ZrO2 (Z), TiO2 (T), and SiO2 (S) groups; each one was further subdivided into two subgroups according to nanoparticles concentration, 3wt.% and 7wt.% (Z3, Z7, T3, T7, S3, and S7), 10 specimens of each subgroup. A3-point bending test and Vickers hardness test were used for FS and hardness measurements, respectively. Wear resistance was evaluated by the differences in surface roughness of tested specimens before and after wear test. Two-way and 1-way ANOVA and Bonferroni’s post hoc tests were done for data analysis (α = 0.05). Results. Two-way ANOVA for FS and wear resistance showed that there was a significant interaction between type of nanoparticles and concentration of nanoparticles ( p < 0.001 ) while two-way ANOVA for hardness showed that both type of nanoparticles and concentration of nanoparticles had a significant effect ( p < 0.001 ), while the effect of their interaction was not statistically significant ( p = 0.142 ). 1-way-ANOVA test showed significant increase in FS and wear resistance for all tested groups ( p < 0.001 and p < 0.001 , respectively) except T7 and S7. Also, there was a significant enhancement in hardness for all tested groups ( p < 0.001 ). Conclusion. Modification of light cured composite resin with certain amounts of nanoparticles (3% and 7% of ZrO2 and 3% of TiO2 and SiO2) can be beneficial in improving flexural strength and wear resistance while hardness of composite resin was increased with all NPs additions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.