The purpose of this paper is to study the hygrothermal effect on fatigue behavior of quasi-isotropic carbon/epoxy plain weave aerospace laminates containing artificial flaw under axial tension–tension loading. Dry and wet specimens were tested at tensile load-controlled cyclic loading with a stress ratio R = 0.1 and a load frequency of 7 Hz at room temperature (RT) and at 82℃ under different stress levels. Allowable stiffness change as a failure criterion was used to determine the delamination propagation onset threshold under cyclic tensile loading at each environmental condition. The delamination propagation onset was verified using the ultrasonic imaging (C-Scan) technique. The experimental results show that (1) fatigue life of CFRP specimens was more individually affected by moisture than by temperature and (2) combined moisture and temperature cause a drastic decrease in fatigue life. Finally, an investigation of the effect of hygrothermal conditions on stiffness degradation and damage of composite laminates subjected to tensile fatigue loading has been also carried. On the basis of the residual stiffness degradation, a damage variable was presented and phenomenological damage models were proposed by employing fatigue modulus and secant modulus concepts as measure of material damage.
The objective of this work is to investigate the effects of environmental conditions on the axial fatigue behavior of a carbon/epoxy plain-weave laminate with an embedded flaw subjected to a partially reversed cyclic load (stress ratio R = −0.1) in tension–compression. This specific material is more commonly used in aerospace engineering for the manufacturing of aircraft structural parts, which are directly exposed to various environmental conditions during service. Specific environmental and loading conditions that are appropriate to simulate real-life conditions are considered to observe and collect information about the material's behavior. For the investigation, dry and wet coupons were submitted to room temperature, 82 and 121 ℃ under loading frequencies of 7 and 15 Hz. A maximum allowable strain increase criterion is used to monitor the flaw growth threshold or delamination onset, during fatigue testing. The ultrasonic imaging (C-scan) technique is used to verify and confirm the delamination onset. Results show that the delamination onset strain increase criterion, along with fatigue life, generally decreased as the operating temperature and humidity were increased and that frequency had little effect on the delamination onset fatigue life. The S– N curves obtained from the tension–compression fatigue data were then compared to those of a previous work carried out in tension–tension fatigue loading. Results show a clear degradation in the delamination onset fatigue life of the coupons tested under tension–tension cyclic loading when the minimum tensile component of the cyclic load was replaced with a compressive load of the same magnitude.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.