This study was done to investigate the relationship between Indoor Air Quality (IAQ) and prevalence of Sick Building Syndrome (SBS) in two different offices (old and new) in Selangor. Hundred and seventy workers were selected consist of 85 office workers for each building. Questionnaire based on Indoor Air Quality and Work Symptoms Survey, NIOSH, Indoor Environmental Quality Survey, 1991 was used to record prevalence of SBS. Measurement of indoor air quality was performed using instruments recommended by IAQ Code of Practice, Department of Occupational Safety and Health, Malaysia. IAQ supplied air was significantly higher in new building with the median 22.49 cfm/person while 15.79 cfm/person in old building (z = -6.23, p<0.001). The prevalence of SBS in old building was significantly higher compared to the new building (χ 2 = 30.6, p<0.001). Levels of indoor air pollutants in old building were significantly higher compared to new building for: CO 2 (z = -4.62, p<0.001); TVOC (z = -2.71, p<0.05); PM 10 (z = -2.11, p<0.05); PM 2.5 (z = -2.35, p<0.05), meanwhile for UFP (z = 4.72, p<0.001) and THI value (z = -4.57, p<0.001), new building was significantly higher compared to old building. There was significant association between the prevalence of SBS and the indoor air pollutants in the old building namely CO 2 (OR = 3.56, 95% CI = 1.327-9.548); CO (OR = 4.95, 95% CI = 1.740-14.127); TVOC (OR = 4.71, 95% CI = 1.571-14.151); PM 10 (OR = 6.23, 95% CI = 2.278-17.065) and PM 2.5 (OR = 4.18, 95% CI = 1.564-11.199), while in the new building, the prevalence of SBS showed significant association with an indoor air pollutant namely UFP (OR = 6.53, 95% CI = 1.757-24.327). After controlling the cofounders; age, medical condition, smoking and having pet at home, the results showed that CO 2 , CO, TVOC, PM 10 , PM 2.5 influenced SBS in old building while UFP influenced SBS in the new building. This study suggested that when there was an increase in the ventilation rates per person in office building, it would significantly reduced prevalence of SBS, even though both buildings meet the existing ASHRAE ventilation standards for office building. Reduction in prevalence of SBS would depend on the increase in ventilation rates, ventilation effectiveness and reduction in indoor air pollutants that can cause SBS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.