Endotoxic material, commonly associated to biological reactions, is thought to be one of the most important constituents in water. This has become a very important topic because of the common interest in microbial products governed by the possible shift to water reuse for drinking purposes. In this light, this study was conducted to provide an assessment of endotoxic activity in reclaimed wastewater. A bacterial endotoxin test (LAL test) was applied to water samples from several wastewater treatment plants (WWTP) in Sapporo, Japan keeping in view the seasonal variation. Samples were taken from several points in WWTP (influent, effluent, return sludge, advanced treatment effluent). The findings of this study indicated that wastewater shows high endotoxin activity. The value of Endotoxin (Endo) to COD ratio in the effluent is usually higher than that of the influent. Moreover, it is found that wastewater contains initially endotoxic active material. Some of those chemicals are biodegradable and but most of them are non-biodegradable. Batch scale activated sludge studies were undertaken to understand the origin of endotoxic active material in the effluent. This study showed that those chemicals are mainly produced during biological reactions, more precisely during decay process. Moreover, raw wastewater (RWW) contains high amounts of organic matter having endotoxicity which remains in the effluent.
Urine is rich in nutrients and can be applied as a fertilizer. The limitation on the application is the transportation cost for the farmlands. The cost estimation required 80% of the volume reduction for a feasible utilization of urine in the farmlands near urban areas. The volume reduction system by forward osmosis (FO) process was proposed to address this problem. In this study, the experiments on FO process with real and synthetic hydrolysed urine were performed to assess the FO performances, to evaluate the solute diffusion and to describe the water flux considering the activity of solutes. This study showed both real and synthetic urine can be concentrated to 2-5 times with 2-5 mol/L sodium chloride solution. High diffusivity of ammonia and carbonates were observed, but the diffusion of other solutes was low. The activities of the solutes in the non-ideal solution should be considered for estimation of the osmotic pressure of the solution which reflects the water flux. The software PHRE-EQC can be used for estimation of the activities in such high concentration solutions. The organic matter in real hydrolysed urine had a negligible effect on the osmotic pressure variations.
Cyclic voltammetry (CV) was used in this work to describe the electrochemical behavior of a dual-chamber microbial fuel cell (MFC). The system performance was evaluated under vacuum and non-pressurized conditions, different reaction times, two sweep potentials, 25 and 50 mVs−1 and under different analyte solutions, such as distilled water and domestic wastewater. CV experiments were conducted by using a potentiostat with three different configurations to collect the measurements. A dual-chamber MFC system was equipped with a DupontTM Nafion® 117 proton exchange membrane (PEM), graphite electrodes (8.0 cm × 2.5 cm × 0.2 cm) and an external electric circuit with a 100-Ω resistor. An electrolyte (0.1 M HCl, pH ≈ 1.8) was used in the cathode chamber. It was found that the proton exchange membrane plays a major role on the electrochemical behavior of the MFC when CV measurements allow observing the conductivity performance in the MFC in the absence of a reference electrode; under this potentiostat setting, less current density values are obtained on the scanned window potentials. Therefore, potentiostat setting is essential to obtain information in complex electrochemical processes present in biological systems, such as it is the case in the MFCs. Results of the study showed that wastewater constituents and the biomass suspended or attached (biofilm) over the electrode limited the electron charge transfer through the interface electrode-biofilm-liquor. This limitation can be overcome by: (i) Enhancing the conductivity of the liquor, which is a reduction of the ohmic drop, (ii) reducing the activation losses by a better catalysis, and (iii) by limiting the diffusional gradients in the bulk liquor, for instance, by forced convection. The use of the electrolyte (0.1 M HCl, pH ≈ 1.8) and its diffusion from the cathode to the anode chamber reduces the resistance to the flow of ions through the PEM and the flow of electrons through the anodic and cathodic electrolytes. Also reduces the activation losses during the electron transfer from the substrate to the electrode surface due to the electrode catalysis improvement. On the other hand, vacuum also demonstrated that it enhances the electrochemical performance of the dual-chamber MFC due to the fact that higher current densities in the system are favored.
As wastewater reclamation and reuse becomes more widespread, risks of exposure to treated wastewater increase. Moreover, an unlimited number of pollutants can be identified in wastewater. Therefore, comprehensive toxicity assessment of treated wastewater is imperative. The objective of this study was to perform a comprehensive toxicity assessment of wastewater treatment systems using stress response 10 bioassays. This powerful tool can comprehensively assess the toxicity of contaminants. In this study, samples from conventional activated sludge treatment, membrane bioreactors (MBRs) with different pore sizes and sludge retention times (SRTs), rapid sand filtration, coagulation, nano-filtration (NF) and reverse osmosis (RO) were investigated. The results of stress response bioassays confirmed that the secondary effluent showed higher stress response than influent indicating that biological treatment 15 generates toxic compounds. The results obtained from molecular weight fractionation of water samples demonstrated that organic matter with a higher molecular weight fraction (>0.1μm) causes toxicity in secondary effluent. Furthermore, supernatant from MBR reactors showed toxicity regardless of SRT. On the other hand, stress response was not detected in MBR permeates except for an MBR equipped with a larger pore size membrane (0.4μm) and with a short SRT (12 days). While rapid sand filtration could not 20 remove the toxic compounds found in secondary effluent, coagulation tests, operated at an appropriate pH, were effective for reducing stress response in the secondary effluent. Experimental findings also showed that stress response was not detected in cases of NF and RO permeate subsequent to MBR treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.