The objective of this study was to demonstrate the potential benefits of using high energy x-rays for phase sensitive breast imaging through a comparison with conventional mammography imaging. We compared images of a contrast-detail (CD) phantom acquired on a prototype phase sensitive x-ray imaging system with images acquired on a commercial flat panel digital mammography unit. The phase contrast images were acquired using a micro-focus x-ray source with a 50 μm focal spot at 120 kVp and 4.5 mAs, with a magnification factor of 2.46 and a 50 μm pixel pitch. A phase attenuation duality (PAD)-based phase retrieval algorithm that requires only a single phase contrast image was applied. Conventional digital mammography images were acquired at 27 kVp, 131 mAs and 28 kVp, 54 mAs. For the same radiation dose, both the observer study and SNR/FOM comparisons indicated a large improvement by the phase retrieved image as compared to the clinical system for the larger disk sizes, but the improvement was not enough to detect the smallest disks. Compared to the double dose image acquired with the clinical system, the observer study also indicated that the phase retrieved image provided improved detection capabilities for all disk sizes except the smallest disks. Thus the SNR improvement provided by phase contrast imaging is not yet enough to offset the noise reduction provided by the clinical system at the doubled dose level. However, the potential demonstrated by this study for high energy phase sensitive x-ray imaging to improve lesion detection and reduce radiation dose in mammography warrants further investigation of this technique.
The ability of microbubbles to benefit the imaging quality of high-energy in-line phase contrast as compared with conventional low-energy contact mode radiography was investigated. The study was conducted by comparing in-line phase contrast imaging with conventional contact-mode projection imaging under the same dose delivered to a phantom. A custom-designed phantom was employed to simulate a segment of human blood vessel injected with microbubble suspensions. The microbubbles were suspended in deionized water to obtain different volume concentrations. The area contrast-to-noise ratio (CNR) values corresponding to both imaging methods were measured for different microbubble volume concentrations. The phase contrast images were processed by phase-attenuation duality phase retrieval to preserve the imaging quality. Comparison of the resultant CNR values indicates that the microbubble suspension images deliver a higher CNR than the water-only image, with monotonically increasing trends between the CNR values and microbubble concentrations. Compared to low-energy conventional images of the microbubble suspensions, high-energy in-line phase contrast CNRs are lower at high concentrations and are comparable, even better than, at low concentrations. This result suggests that 1) the performance of copolymer-shell microbubble employed in this study as x-ray contrast agent is constrained by the detective quantum efficiency of the system and the attenuation properties of the shell materials, 2) the phase-attenuation duality phase retrieval method has the potential to preserve image quality for areas with low concentration of microbubbles, and 3) the selection of microbubble products as a phase contrast agent may follow criteria of minimizing the impact of absorption attenuation properties of the shells and maximizing the difference factor of electron densities.
This research successfully demonstrated a high-energy in-line phase contrast tomosynthesis prototype. In addition, the PAD-based method of phase retrieval was combined with tomosynthesis imaging for the first time, which demonstrated its capability in significantly improving the contrast-to-noise ratios in the images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.