The novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is highly infectious, carries significant morbidity and mortality, and has rapidly resulted in strained health care system and hospital resources. In addition to patientrelated care concerns in infected individuals, focus must also relate to diminishing community spread, protection of staff, case selection, and concentration of resources. The current document based on available data and consensus opinion addresses appropriate catheterization laboratory preparedness for treating these patients, including procedure-room readiness to minimize external contamination, safe donning and doffing of personal protective equipment (PPE) to eliminate risk to staff, and staffing algorithms to minimize exposure and maximize team availability.Case selection and management of both emergent and urgent procedures are discussed in detail, including procedures that may be safely deferred or performed bedside. K E Y W O R D S coronavirus, cathlab readiness, PPE
Background
Despite clinical trial evidence and clinical experience supporting the efficacy of transcatheter aortic valve replacement (TAVR), data demonstrating the benefit of TAVR specifically in the very elderly patients are limited, as they often represent only a small proportion of the clinical trial populations.
Objectives
To compare the outcomes of nonagenarians to younger patients undergoing TAVR in current clinical practice.
Methods
National U.S. data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy (STS/ACC TVT) Registry were analyzed. Outcomes at 30-days and 1-year were compared between patients ≥90 vs <90 years of age using cumulative incidence curves. Quality of life was assessed with the 12-item Kansas City Cardiomyopathy Questionnaire (KCCQ-12).
Results
Between November 2011 and September 2014, 24,025 patients underwent TAVR in 329 participating hospitals, of which 3,773 (15.7%) were age ≥90. The 30-day and 1-year mortality was significantly higher among nonagenarians (≥90 vs. <90: 30-day: 8.8% vs. 5.9%, p<0.001; 1-year: 24.8% vs. 22.0%, p<0.001, absolute risk 2.8%, relative risk 12.7%). However, nonagenarians had a higher mean STS PROM score(10.9% vs. 8.1%; p<0.001) and therefore had similar ratios of observed to expected rates of 30-day death (≥90 vs. <90: 0.81, 95% CI 0.70–0.92 vs. 0.72, 95% CI 0.67–0.78). There were no differences in the rates of stroke, aortic valve reintervention or myocardial infarction at 30-days or 1-year. Nonagenarians had lower (worse) median KCCQ-12 scores at 30-days; however, there was no significant difference at 1-year.
Conclusions
In current U.S. clinical practice, approximately 16% of patients undergoing TAVR are ≥90 years of age. Although 30-day and 1-year mortality was statistically higher compared with younger patients undergoing TAVR, the absolute and relative differences were clinically modest. TAVR also improves quality of life to the same degree in nonagenarians as in younger patients. These data support safety and efficacy of TAVR in select very elderly patients.
Background:
Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device.
Methods and Results:
A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%).
Conclusions:
In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices.
Clinical Trial Registration:
URL:
https://www.clinicaltrials.gov
. Unique identifier: NCT02908880.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.