The mechanics of great subduction earthquakes are influenced by the frictional properties, structure, and composition of the plate-boundary fault. We present observations of the structure and composition of the shallow source fault of the 2011 Tohoku-Oki earthquake and tsunami from boreholes drilled by the Integrated Ocean Drilling Program Expedition 343 and 343T. Logging-while-drilling and core-sample observations show a single major plate-boundary fault accommodated the large slip of the Tohoku-Oki earthquake rupture, as well as nearly all the cumulative interplate motion at the drill site. The localization of deformation onto a limited thickness (less than 5 meters) of pelagic clay is the defining characteristic of the shallow earthquake fault, suggesting that the pelagic clay may be a regionally important control on tsunamigenic earthquakes.
The 2011 Mw9.0 Tohoku‐oki earthquake ruptured to the trench with maximum coseismic slip located on the shallow portion of the plate boundary fault. To investigate the conditions and physical processes that promoted slip to the trench, Integrated Ocean Drilling Program Expedition 343/343T sailed 1 year after the earthquake and drilled into the plate boundary ∼7 km landward of the trench, in the region of maximum slip. Core analyses show that the plate boundary décollement is localized onto an interval of smectite‐rich, pelagic clay. Subsidiary structures are present in both the upper and lower plates, which define a fault zone ∼5–15m thick. Fault rocks recovered from within the clay‐rich interval contain a pervasive scaly fabric defined by anastomosing, polished, and lineated surfaces with two predominant orientations. The scaly fabric is crosscut in several places by discrete contacts across which the scaly fabric is truncated and rotated, or different rocks are juxtaposed. These contacts are inferred to be faults. The plate boundary décollement therefore contains structures resulting from both distributed and localized deformation. We infer that the formation of both of these types of structures is controlled by the frictional properties of the clay: the distributed scaly fabric formed at low strain rates associated with velocity‐strengthening frictional behavior, and the localized faults formed at high strain rates characterized by velocity‐weakening behavior. The presence of multiple discrete faults resulting from seismic slip within the décollement suggests that rupture to the trench may be characteristic of this margin.
The 2011 moment magnitude 9.0 Tohoku-Oki earthquake produced a maximum coseismic slip of more than 50 meters near the Japan trench, which could result in a completely reduced stress state in the region. We tested this hypothesis by determining the in situ stress state of the frontal prism from boreholes drilled by the Integrated Ocean Drilling Program approximately 1 year after the earthquake and by inferring the pre-earthquake stress state. On the basis of the horizontal stress orientations and magnitudes estimated from borehole breakouts and the increase in coseismic displacement during propagation of the rupture to the trench axis, in situ horizontal stress decreased during the earthquake. The stress change suggests an active slip of the frontal plate interface, which is consistent with coseismic fault weakening and a nearly total stress drop.
There is a global seismic moment deficit on mid-ocean ridge transform faults, and the largest earthquakes on these faults do not rupture the full fault area. We explore the influence of physical fault structure, including step-overs in the fault trace, on the seismic behavior of the Discovery transform fault, 4S on the East Pacific Rise. One year of microseismicity recorded during a 2008 ocean bottom seismograph deployment (24,377 0 M L 4.6 earthquakes) and 24 years of Mw 5.4 earthquakes obtained from the Global Centroid Moment Tensor catalog, are correlated with surface fault structure delineated from high-resolution multibeam bathymetry. Each of the 15 5.4 Mw 6.0 earthquakes that occurred on Discovery between 1 January 1990 and 1 April 2014 was relocated into one of five distinct rupture patches using a teleseismic surface wave cross-correlation technique. Microseismicity was relocated using the HypoDD relocation algorithm. The western fault segment of Discovery (DW) is composed of three zones of varying structure and seismic behavior: a zone with no large events and abundant microseismicity, a fully coupled zone with large earthquakes, and a complex zone with multiple fault strands and abundant seismicity. In general, microseismicity is reduced within the patches defined by the large, repeating earthquakes. While the extent of the large rupture patches on DW correlates with physical features in the bathymetry, step-overs in the primary fault trace are not observed at patch boundaries, suggesting along-strike heterogeneity in fault zone properties controls the size and location of the large events.
Earthquakes occur by overcoming fault friction; therefore, quantifying fault resistance is central to earthquake physics. Values for both static and dynamic friction are required, and the latter is especially difficult to determine on natural faults. However, large earthquakes provide signals that can determine friction in situ. The Japan Trench Fast Drilling Project (JFAST), an Integrated Ocean Discovery Program expedition, determined stresses by collecting data directly from the fault 1–2 years after the 2011 Mw 9.1 Tohoku earthquake. Geological, rheological, and geophysical data record stress before, during, and after the earthquake. Together, the observations imply that the shear strength during the earthquake was substantially below that predicted by the traditional Byerlee's law. Locally the stress drop appears near total, and stress reversal is plausible. Most solutions to the energy balance require off-fault deformation to account for dissipation during rupture. These observations make extreme coseismic weakening the preferred model for fault behavior. ▪ Determining the friction during an earthquake is required to understand when and where earthquakes occur. ▪ Drilling into the Tohoku fault showed that friction during the earthquake was low. ▪ Dynamic friction during the earthquake was lower than static friction. ▪ Complete stress drop is possible, and stress reversal is plausible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.