Although Meigs’ syndrome is regarded as a well-defined entity, contradictory data on pleural fluid characteristics have been presented, with some papers classifying it as a transudate, whereas others stating that it is an exudate.The aims of the study were: (1) to evaluate pleural fluid characteristics in patients with Meigs’ syndrome and (2) to analyze the prevalence of transudative and exudative pleural effusion in relation to the applied definition of the syndrome.We performed a search through medical databases (MEDLINE, EMBASE, SCOPUS, and GOOGLE SCHOLAR) to identify papers on Meigs’ syndrome published between 1940 and 2013. Two authors independently reviewed each paper searching for prespecified data: (1) signs and symptoms, (2) tumor characteristics, (3) clinical and laboratory data on ascites, (4) clinical, radiological, and laboratory data on pleural fluid, (5) clinical course after tumor removal. All case reports were reclassified according to a new unequivocal classification of Meigs’ syndrome-related entities.A total of 653 papers were initially identified, and 454 articles reporting 541 patients were included in the final analysis. After reclassification according to our case definitions, there were 196, 113, and 108 patients defined as classic Meigs’ syndrome, nonclassic Meigs’ syndrome, and pseudo-Meigs’ syndrome, respectively. Significantly more patients presented with right-sided than left-sided and bilateral pleural effusions (P < 0.001). Median volume of withdrawn pleural fluid was 2950 (1500–6000) mL. The classification of pleural effusion with the use of Light's criteria was possible in only 7 patients. In 6 of these patients pleural effusion met the criteria for an exudate. When the protein concentration > 3.0 g/dL was applied as a criterion of pleural exudate, 88.8% (80/90) of effusions were classified as exudates. Increasing the cut-off level to 3.5 g/dL resulted in only a modest decrease in the percentage of exudative effusions (81%, 73/90).Surprisingly few reports on Meigs’ syndrome present data reliably defining the character of pleural effusion. The available data indicate, however, that the majority of pleural effusions in patients with this entity are exudates. This finding may be a prerequisite for the verification of some earlier presented concepts.
Subatmospheric pleural pressure (Ppl), which is approximately -3 to -5 cmHO at functional residual capacity (FRC) makes pleura a unique organ in the human body. The negative Ppl is critical for maintaining the lungs in a properly inflated state and for proper blood circulation within the thorax. Significant and sudden pleural pressure changes associated with major pleural pathologies, as well as therapeutic interventions may be associated with life-threatening complications. The pleural pressure may show two different values depending on the measurement method applied. These are called pleural liquid pressure and pleural surface pressure. It should also be realized that there are significant differences in pleural pressure distribution in pneumothorax and pleural effusion. In pneumothorax, the pressure is the same throughout the pleural space, while in pleural effusion there is a vertical gradient of approximately 1 cm HO/cm in the pleural pressure associated with the hydrostatic pressure of the fluid column. Currently, two main methods of pleural pressure measurement are used: simple water manometers and electronic systems. The water manometers are conceptually simple, cheap and user-friendly but they only allow the estimation of the mean values of pleural pressure. The electronic systems for pleural pressure measurement are based on pressure transducers. Their major advantages include precise measurements of instantaneous pleural pressure and the ability to display and to store a large amount of data. The paper presents principles and details of pleural pressure measurement as well as the rationale for its use.
Although pleural manometry is a relatively simple medical procedure it is only occasionally used to follow pleural pressure (Ppl) changes during a therapeutic thoracentesis and pneumothorax drainage. As some studies showed that pleural pressure monitoring might be associated with significant advantages, pleural manometry has been increasingly evaluated in the last decade. The major clinical applications of pleural pressure measurements include: the prevention of complications associated with large volume thoracentesis, diagnosis and differentiation between various types of an unexpandable lung and a possible prediction of the efficacy of chest tube drainage in patients with spontaneous pneumothorax. It is well known that the therapeutic thoracentesis might be complicated by cough, chest discomfort, and rarely, by a life threatening condition called reexpansion pulmonary edema (RPE). The serious adverse events of thoracentesis are related to pleural pressure drop rather than to the volume of removed pleural effusion. The use of pleural manometry during pleural fluid withdrawal enables the evaluation of the relationship between withdrawn pleural fluid volume, pleural pressure changes and procedure related complications. Pleural pressure measurement is also an important tool to study the different mechanism of pneumothorax complicating the thoracentesis. Pleural manometry is critical for measurement of pleural elastance, diagnosis of an unexpandable lung and differentiation between trapped lung and lung entrapment. This usually has significant clinical implications in terms of further management of patients with pleural effusion. The paper is a comprehensive review presenting different aspects of pleural pressure measurement in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.