Story-added type apartments have recently been introduced as an option to resolve the housing supply shortage in areas that are undergoing rapid industrialization and urbanization. However, the infrastructure of old apartment buildings (>20 years old) makes it difficult to introduce convenient facilities and recent technologies such as those involving the Internet of Things and augmented realities. Applying housing technologies to existing older apartments can increase housing supply and potentially address the aforementioned issues. However, story-added building remodeling increases the weight of existing buildings, necessitating seismic reinforcement, which is the major obstacle when performing vertical building extensions. This study presents methods for lowering seismic loads associated with vertical augmentation of buildings while improving the seismic performance. A model of a vertically extended building with three additional stories constructed on top of an existing 15-story apartment building was used. The applied seismic isolation system decreased the maximum response acceleration on top of the remodeled building by approximately 70% and 65% in the X-direction and Y-direction, respectively, while decreasing the base shear plane by approximately 30% in both the X- and Y-directions in comparison with forces on a non-seismically isolated building. These results demonstrate that the use of a seismic isolation system can significantly reduce seismic loads.
Abstract. Recently, extinguishing system installed in the building when the earthquake occurred at a separate performance requirements. Before the building collapsed during the earthquake, as a function to maintain a fire extinguishing. In particular, the automatic sprinkler fire extinguishing equipment, such as after a massive earthquake without damage to piping also must maintain confidentiality. In this study, an experiment installed in the building during the earthquake, the water-based fire extinguishing saw grasp the impact of the pipe. Experimental structures for water-based fire extinguishing seismic construction step by step, and then applied to the seismic experiment, the building appears in the extinguishing of the earthquake response of the pipe was measured. Construction of acceleration caused by vibration being added to the size and the size of the displacement is measured and compared with the data response of the pipe from the table, thereby extinguishing water piping need to enhance the seismic analysis. Define the seismic design category (SDC) for the four groups in the building structure with seismic criteria (KBC2009) designed according to the importance of the group and earthquake seismic intensity. The event of a real earthquake seismic analysis of Category A and Category B for the seismic design of buildings, the current fire-fighting facilities could have also determined that the seismic performance. In the case of seismic design categories C and D are installed in buildings to preserve the function of extinguishing the required level of seismic retrofit design is determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.