Atrial fibrillation (AF) and heart failure (HF) are two common conditions that often coexist and predispose each to one another. AF increases hospitalization rates and overall mortality in patients with HF. The current available therapeutic options for AF in patients with HF are diverse and guidelines do not provide a clear consensus regarding the best management approach. To determine if catheter ablation for AF is superior to medical therapy alone in patients with coexisting HF, we conducted this systematic review and meta-analysis. The primary outcomes evaluated are left ventricular ejection fraction (LVEF), Minnesota Living with Heart Failure Questionnaire (MLWHFQ) scores, 6-minute walk test (6MWT) distance, heart failure hospitalizations, and mortality. The results are presented as a mean difference for continuous outcome measures and odds ratios for dichotomous outcomes (using Mantel-Haenszel random effects model). 7 full texts met inclusion criteria, including 856 patients. AF catheter ablation was associated with a significant increase in LVEF (mean difference 6.8%; 95% CI: 3.5 – 10.1; P<0.001) and 6MWT (mean difference 29.3; 95% CI: 11.8 – 46.8; P = 0.001), and improvement in MLWHFQ (mean difference -12.1; 95% CI: -20.9 – -3.3; P = 0.007). The risk of all-cause mortality was significantly lower in the AF ablation arm (OR 0.49; 95% CI: 0.31 – 0.77; P = 0.002). In conclusion, atrial fibrillation ablation in patients with systolic heart failure is associated with significant improvement in LVEF, quality of life, 6MWT, and overall mortality.
The objective of this study is to compare hemodynamic performances under different pulsatile control algorithms between Medos DeltaStream DP3 and i‐cor diagonal pumps in simulated pediatric and adult ECLS systems. An additional pilot study was designed to test hemolysis using two pumps during 12h‐ECLS. The experimental circuit consisted of parallel combined pediatric and adult ECLS circuits using an i‐cor pump head and either an i‐cor console or Medos DeltaStream MDC console, a Medos Hilite 2400 LT oxygenator for the pediatric ECLS circuit, and a Medos Hilite 7000 LT oxygenator for the adult ECLS circuit. The circuit was primed with lactated Ringer's solution and human packed red blood cells (hematocrit 40%). Trials were conducted at various flow rates (pediatric circuit: 0.5 and 1L/min; adult circuit: 2 and 4L/min) under nonpulsatile and pulsatile modes (pulsatile amplitude: 1000–5000rpm [1000 rpm increments] for i‐cor pump, 500–2500rpm [500 rpm increments] for Medos pump) at 36°C. In an additional protocol, fresh whole blood was used to test hemolysis under nonpulsatile and pulsatile modes using the two pump systems in adult ECLS circuits. Under pulsatile mode, energy equivalent pressures (EEP) were always greater than mean pressures for the two systems. Total hemodynamic energy (THE) and surplus hemodynamic energy (SHE) levels delivered to the patient increased with increasing pulsatile amplitude and decreased with increasing flow rate. The i‐cor pump outperformed at low flow rates, but the Medos pump performed superiorly at high flow rates. There was no significant difference between two pumps in percentage of THE loss. The plasma free hemoglobin level was always higher in the Medos DP3 pulsatile group at 4 L/min compared to others. Pulsatile control algorithms of Medos and i‐cor consoles had great effects on pulsatility. Although high pulsatile amplitudes delivered higher levels of hemodynamic energy to the patient, the high rotational speeds increased the risk of hemolysis. Use of proper pulsatile amplitude settings and intermittent pulsatile mode are suggested to achieve better pulsatility and decrease the risk of hemolysis. Further optimized pulsatile control algorithms are needed.
The objective of this study was to assess the hemodynamic properties of the i-cor ECG-synchronized cardiac assist system for off-label use as a short-term cardiac assist device for neonatal and pediatric patients and compare nonpulsatile to pulsatile flow with different amplitudes. The circuit consisted of the i-cor diagonal pump with 3 feet of ¼ inch arterial and venous tubing and a soft-shell reservoir, primed with lactated Ringer's solution and human packed red blood cells (hematocrit 42%). Trials were conducted with three different sets of cannulas (8-Fr arterial 10-Fr venous, 10-Fr arterial 12 Fr-venous, and 12-Fr arterial 14-Fr venous) with increasing flow rates at varying pseudo-patient pressures (40, 60, 80, and 100 mm Hg) and under nonpulsatile mode and pulsatile mode with pulsatile amplitudes 2000, 2500, and 3000 rpm at 36°C. Pressure and flow waveforms were recorded using a custom-made data acquisition device for each trial. Energy equivalent pressure (EEP) was higher than mean pressure under pulsatile mode, and increased with increasing pseudo-patient's pressure and flow rate while EEP was the same as the mean pressure under nonpulsatile mode. Total hemodynamic energy (THE) levels increased with pressure and pulsatile amplitude and slightly decreased with increasing flow rate. The percent THE lost throughout the circuit increased with flow rate and pulsatile amplitude and decreased with pseudo-patient's pressure. SHE levels also increased with pseudo-patient pressure and pulsatile amplitude and decreased with increasing flow rate. The i-cor diagonal pump can be used as a short term cardiac assist device for neonatal and pediatric patients and is able to provide nonpulsatile as well as pulsatile flow. Compared with nonpulsatile flow, pulsatile flow can generate and deliver more hemodynamic energy to the patients.
The objective of this study was to evaluate three commercially available ECLS systems with rotary pumps in terms of circuit pressure, pressure drop, perfusion modes, and hemodynamic energy transmission in a simulated adult cardiogenic shock model. One circuit consisted of a Cardiohelp system, which included a Cardiohelp console and HLS Module Advanced 7.0 tubing set with integrated centrifugal pump and oxygenator. The alternative circuit was composed of a Quadrox-D Adult oxygenator connected in series with either an i-cor diagonal pump and console or a Rotaflow centrifugal pump and console. The circuit was primed with lactated Ringer's solution and packed red blood cells (hematocrit 40%). The trials were conducted at flow rates of 1-5 L/min with pseudo patient pressures of 60 mm Hg and 80 mm Hg. Pulsatile flow was tested when using the i-cor system. Mean pre-oxygenator pressure and pressure drop across ECLS circuit (including oxygenator and arterial tubing) were lower when using the Cardiohelp system as compared to the Rotaflow and i-cor systems (P < 0.01). The i-cor system was able to deliver more hemodynamic energy to the pseudo patient because of its ability to produce pulsatile flow (P < 0.01). The Cardiohelp HLS Module Advanced 7.0 integrated oxygenator had a lower resistance than the Quadrox-D oxygenator. Although the compact Cardiohelp system had a better hemodynamic performance when compared to Rotaflow and i-cor systems, the pulsatile flow of the i-cor system delivered more hemodynamic energy to the pseudo patient. This may render more physiological benefits in high-risk patients on ECLS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.