In patients who experience unilateral chronic pain, abnormal sensory perception at the non-painful side has been reported. Contralateral sensory changes in these patients have been given little attention, possibly because they are regarded as clinically irrelevant. Still, bilateral sensory changes in these patients could become clinically relevant if they challenge the correct identification of their sensory dysfunction in terms of hyperalgesia and allodynia. Therefore, we have used the standardized quantitative sensory testing (QST) protocol of the German Research Network on Neuropathic Pain (DFNS) to investigate somatosensory function at the painful side and the corresponding non-painful side in unilateral neuropathic pain patients using gender- and age-matched healthy volunteers as a reference cohort. Sensory abnormalities were observed across all QST parameters at the painful side, but also, to a lesser extent, at the contralateral, non-painful side. Similar relative distributions regarding sensory loss/gain for non-nociceptive and nociceptive stimuli were found for both sides. Once a sensory abnormality for a QST parameter at the affected side was observed, the prevalence of an abnormality for the same parameter at the non-affected side was as high as 57% (for Pressure Pain Threshold). Our results show that bilateral sensory dysfunction in patients with unilateral neuropathic pain is more rule than exception. Therefore, this phenomenon should be taken into account for appropriate diagnostic evaluation in clinical practice. This is particularly true for mechanical stimuli where the 95% Confidence Interval for the prevalence of sensory abnormalities at the non-painful side ranges between 33% and 50%.
The study aimed to determine the associations of Peak Inspiratory Flow (PIF), inhalation technique and adherence with health status and exacerbations in participants with COPD using DPI maintenance therapy. This cross-sectional multi-country observational real-world study included COPD participants aged ≥40 years using a DPI for maintenance therapy. PIF was measured three times with the In-Check DIAL G16: (1) typical PIF at resistance of participant’s inhaler, (2) maximal PIF at resistance of participant’s inhaler, (3) maximal PIF at low resistance. Suboptimal PIF (sPIF) was defined as PIF lower than required for the device. Participants completed questionnaires on health status (Clinical COPD Questionnaire (CCQ)), adherence (Test of Adherence to Inhalers (TAI)) and exacerbations. Inhalation technique was assessed by standardised evaluation of video recordings. Complete data were available from 1434 participants (50.1% female, mean age 69.2 years). GOLD stage was available for 801 participants: GOLD stage I (23.6%), II (54.9%), III (17.4%) and IV (4.1%)). Of all participants, 29% had a sPIF, and 16% were shown able to generate an optimal PIF but failed to do so. sPIF was significantly associated with worse health status (0.226 (95% CI 0.107–0.346), worse units on CCQ; p = 0.001). The errors ‘teeth and lips sealed around mouthpiece’, ‘breathe in’, and ‘breathe out calmly after inhalation’ were related to health status. Adherence was not associated with health status. After correcting for multiple testing, no significant association was found with moderate or severe exacerbations in the last 12 months. To conclude, sPIF is associated with poorer health status. This study demonstrates the importance of PIF assessment in DPI inhalation therapy. Healthcare professionals should consider selecting appropriate inhalers in cases of sPIF.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.