Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with different numbers of lengthwise slits and different screw expansion levels were evaluated. Synthetic bones simulating severe osteoporosis were used to provide a comparative platform for each screw design. The prepared specimens were then tested for axial pullout failure. Regardless of screw design, screws with cement augmentation demonstrated significantly higher pullout strength than pedicle screws without cement augmentation (p < 0.001). For screws without cement augmentation, solid screws exhibited the lowest pullout strength compared to the four expansive groups (p < 0.01). No significant differences in pullout strength were observed between the expansive screws with different designs (p > 0.05). Taken together, our results show that pedicle screws combined with cement augmentation may greatly increase screw fixation regardless of screws with or without expansion. An increase in both the number of slits and the extent of screw expansion had little impact on the screw-anchoring strength. Cement augmentation is the most influential factor for improving screw pullout strength.
Screw loosening due to broken pedicles is a common complication resulting from the insertion of screws either with inadequate diameters or into an osteoporotic pedicle. In this novel in vitro study, we tried to clarify the contribution of the pedicle to screw fixation and subsequent salvage strategies using longer or larger-diameter screws in broken pedicles. Sixty L4 fresh-frozen lumbar vertebrae harvested from mature pigs were designed as the normal-density group (n = 30) and decalcified as the osteoporosis group (n = 30). Three modalities were randomly assigned as intact pedicle (n = 30), semi-pedicle (n = 15), and non-pedicle (n = 15) in each group. Three sizes of polyaxial screws (diameter × length of 6.0 mm × 45 mm, 6.0 mm × 50 mm, and 6.5 mm × 45 mm) over five trials were used in each modality. The associations between bone density, pedicle modality and screw pullout strength were analyzed. After decalcification for 4 weeks, the area bone mineral density decreased to approximately 56% (p < 0.05) of the normal-density group, which was assigned as the osteoporosis group. An appropriate screw trajectory and insertional depth were confirmed using X-ray imaging prior to pullout testing in both groups. The pullout forces of larger-diameter screws (6.5 mm × 45 mm) and longer screws (6.0 mm × 50 mm) were significantly higher (p < 0.05) in the semi- and non-pedicle modalities in the normal-density group, whereas only longer screws (6.0 mm × 50 mm) had a significantly higher (p < 0.05) pullout force in the non-pedicle modalities in the osteoporosis group. The pedicle plays an important role in both the normal bone density group and the osteoporosis group, as revealed by analyzing the pullout force percentage contributed by the pedicle. Use of a longer screw would be a way to salvage a broken pedicle of osteoporotic vertebra.
Pedicle screw loosening resulting from insufficient bone-screw interfacial holding power is not uncommon. The screw shape and thread profile are considered important factors of the screw fixation strength. This work investigated the difference in pullout strength between conical and cylindrical screws with three different thread designs. The effects of the thread profiles on the screw fixation strength of cannulated screws with or without cement augmentation in osteoporotic bone were also evaluated. Commercially available artificial standard L4 vertebrae and low-density polyurethane foam blocks were used as substitutes for healthy vertebrae and osteoporotic bones, respectively. The screw pullout strengths of nine screw systems were investigated (six in each). These systems included the combination of three different screw shapes (solid/cylindrical, solid/conical and cannulated/cylindrical) with three different thread profiles (fine-thread, coarse-thread and dual-core/dual-thread). Solid screws were designed for the cementless screw fixation of vertebrae using the standard samples, whereas cannulated screws were designed for the cemented screw fixation of osteoporotic bone using low-density test blocks. Following specimen preparation, a screw pullout test was conducted using a material test machine, and the maximal screw pullout strength was compared among the groups. This study demonstrated that, in healthy vertebrae, both the conical and dual-core/dual-thread designs can improve pullout strength. A combination of the conical and dual-core/dual-thread designs may achieve optimal postoperative screw stability. However, in osteoporotic bone, the thread profile have little impact on the screw fixation strength when pedicle screws are fixed with cement augmentation. Cement augmentation is the most important factor contributing to screw pullout fixation strength as compared to screw designs.
Polymethylmethacrylate (PMMA) bone cement is a popular bone void filler for vertebroplasty. However, the use of PMMA has some drawbacks, including the material's excessive stiffness, exothermic polymerization, and short handling time. This study aimed to create an ideal modified bone cement to solve the above-mentioned problems. Modified bone cements were prepared by combining PMMA with three different volume fractions of castor oil (5%, 10%, and 15%). The peak polymerization temperatures, times to achieve the peak polymerization temperature, porosities, densities, modulus and maximum compression strengths of standard (without castor oil), and modified cements were investigated following storage at ambient temperature (22°C) or under precooling conditions (3°C). Six specimens were tested in each group of the aforementioned parameters. Increasing castor oil content and precooling treatment effectively decreased the peak polymerization temperatures and increased the duration to achieve the peak polymerization temperature (P < 0.05). Furthermore, the mechanical properties of the material, including density, modulus, and maximum compression strength, decreased with increasing castor oil content. However, preparation temperature (room temperature versus precooling) had no significant effect (P > 0.05) on these mechanical properties. In conclusion, the addition of castor oil to PMMA followed by precooling created an ideal modified bone cement with a low modulus, low polymerization temperature, and long handling time, enhancing its applicability and safety for vertebroplasty.
Pedicles are often broken when screws are inserted into hard pedicles with small diameters or when the diameter of the screw itself is inadequate. However, there is a lack of biomechanical literature that addresses screw loosening as a result of broken pedicles or the resulting salvage of those screws. We performed a novel in vitro study to compare the pullout strength of screws between intact pedicles and two different types of broken pedicles; strategies to prevent screw loosening were also compared. Thirty L4 Sawbones were designed to represent intact pedicles, semi-pedicles, and nonpedicles and were prepared for screw insertion. Three sizes of polyaxial screws (diameter × length dimensions of 6.0 mm × 45 mm, 6.0 mm × 50 mm and 6.5 mm × 45 mm) were independently and randomly distributed into the intact-pedicle group (IP group, n = 30), the semi-pedicle group (SP group, n = 15), or the nonpedicle group (NP group, n = 15). The experiments were conducted across a minimum of five trials for each of the chosen screw sizes. We then analyzed the results of the imaging, pullout testing, and embedded bone volume. Any fractures or defects of the vertebrae caused by screw insertion were excluded from the study. The appropriate screw trajectory and insertional depth were confirmed using axial and sagittal X-ray imaging prior to screw pullout testing. A pullout strength of only 41% to 45% for the SP group and 29% to 39% for the NP group was retained following a broken pedicle. The use of longer or larger-diameter screws appears to be an effective salvaging procedure for the NP group ( p < 0.05). The embedded bone volume percentage analysis indicated that, compared to the IP group, 68% to 76% of effective bone embedded into the screw threads in the SP group, and 58% to 65% in the NP group. There was no direct correlation between the pullout strength and the embedded bone volume; however, less effective embedded bone volume was associated with lower pullout strength. This study describes the evolution of the well-established screw pullout test being applied to the broken pedicle Sawbone testing model. The pedicle plays an important role in determining the pullout strength of a screw. However, a salvage procedure that utilizes a longer or larger-diameter screw might be a reliable clinical approach to address broken pedicles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.