BACKGROUNDCoronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. METHODSWe randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. RESULTSAt 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, −0.2 percentage points; 95% confidence interval [CI], −2.3 to 1.8; P<0.001 for noninferiority; hazard ratio, 0.95; 95% CI, 0.68 to 1.33; P = 0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P = 0.001). CONCLUSIONSCoronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. ( Use of Instantaneous Wave-free R atio in PCI F or the past 20 years, physiological measurements obtained during invasive procedures have been used to guide coronary revascularization. Pioneering work supported the use of flow measurements to make safe decisions about revascularization, 1,2 but this approach was soon superseded by the use of fractional flow reserve (FFR), which measures pressure as a surrogate of flow to estimate the severity of stenosis. 3-5 FFR was successful largely because of its technical simplicity and because clinical trials showed that it was associated with improved clinical outcomes after percutaneous coronary intervention (PCI). 6,7 Consequently, FFR is now included in the appropriate-use criteria for coronary angiography and in the American College of Cardiology-American Heart Association-European Society of Cardiology guidelines; despite these recommendations, its adoption remains limited. [8][9][10] FFR must be measured during maximal hyperemia, which is typically induced with the administration of a potent intravenous or intracoronary vasodilator, such as adenosine. 11 Several studies have...
Human sulfite oxidase (hSO) was immobilised on SAM-coated silver electrodes under preservation of the native heme pocket structure of the cytochrome b5 (Cyt b5) domain and the functionality of the enzyme. The redox properties and catalytic activity of the entire enzyme were studied by surface enhanced resonance Raman (SERR) spectroscopy and cyclic voltammetry (CV) and compared to the isolated heme domain when possible. It is shown that heterogeneous electron transfer and catalytic activity of hSO sensitively depend on the local environment of the enzyme. Increasing the ionic strength of the buffer solution leads to an increase of the heterogeneous electron transfer rate from 17 s(-1) to 440 s(-1) for hSO as determined by SERR spectroscopy. CV measurements demonstrate an increase of the apparent turnover rate for the immobilised hSO from 0.85 s(-1) in 100 mM buffer to 5.26 s(-1) in 750 mM buffer. We suggest that both effects originate from the increased mobility of the surface-bound enzyme with increasing ionic strength. In agreement with surface potential calculations we propose that at high ionic strength the enzyme is immobilised via the dimerisation domain to the SAM surface. The flexible loop region connecting the Moco and the Cyt b5 domain allows alternating contact with the Moco interaction site and the SAM surface, thereby promoting the sequential intramolecular and heterogeneous electron transfer from Moco via Cyt b5 to the electrode. At lower ionic strength, the contact time of the Cyt b5 domain with the SAM surface is longer, corresponding to a slower overall electron transfer process.
This study showed that endothelial functions were impaired in patients with chronic periodontitis and that they improve following initial periodontal therapy.
In our pilot trial, the administration of low-dose intracoronary streptokinase immediately after primary PCI improved myocardial reperfusion but not long-term left ventricular size or function. These findings require clarification in a larger trial. (ClinicalTrials.gov number, NCT00302419.)
These results suggest that with advancing stage of lung cancer, the levels of oxidative stress increase, while levels of antioxidant molecules decrease. Patients with squamous cell carcinoma have higher oxidative stress as reflected by higher levels of malondialdehyde and nitrite.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.