The characteristics of high-speed air-entrained jet flow over a spillway aerator were investigated using experimental data. Three different ramp designs (as well as the case of no ramp) were tested in a channel where the bed slope was adjusted to 0, 0.17, and 0.57, respectively. The effects of aerator geometry and flow condition on the air-entrainment process within the water jet and on the pressure fluctuations in the impact region are the main focus of the investigation. An extensive data analysis was performed for data obtained from this study and from a similar laboratory study conducted by another investigator. Experimental relations were derived for nondimensional parameters of jet length, aerator cavity subpressure number, and aeration rates through the lower and upper nappes of the water jet. Scale effects for lower nappe aeration and aerator cavity subpressure number were considered and a good correlation was determined with prototype aerator measurements of Emborcaçao, Foz do Areia, and Keban dams for lower nappe aeration and Guri Dam for aerator cavity subpressure numbers. An aerator without a ramp may be subjected to excessive pressure fluctuations at the impact region due to insufficient air entrainment. Key words: air entrainment, aerator, scale effect, jet length, cavity subpressure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.