Background: The failing Fontan circulation is associated with hepatic impairment. The nature of this liver injury is poorly defined. Objective: To establish the gross and histological liver changes of patients with Fontan circulation relative to clinical, biochemical and haemodynamic findings. Results: Zonal enhancement of the liver (4/12) on CT was more common in patients with lower hepatic vein pressures (p = 0.007), and in those with absent cardiac cirrhosis on histological examination (p = 0.033). Gastro-oesophageal varices (4/12) were more common in patients with higher hepatic vein pressure (21 (6.3) vs 12.2 (2.2) mm Hg, p = 0.013) and associated with more advanced cirrhosis (p = 0.037). The extent of cirrhosis (7/12) was positively correlated with the hepatic vein pressure (r = 0.83, p = 0.003). A significant positive correlation was found between the Fontan duration and the degree of hepatic fibrosis (r = 0.75, p = 0.013), as well as presence of broad scars (r = 0.71, p = 0.021). Protein-losing enteropathy (5/12) occurred more frequently in patients with longer Fontan duration (11.7 (3.2) vs 17.9 (6.1) years, p = 0.038). Conclusions: Liver injury, which can be extensive in this patient group, is related to Fontan duration and hepatic vein pressures. CT scan assists non-invasive assessment. Cardiac cirrhosis with the risk of developing gastro-oesophageal varices and regenerative liver nodules, a precursor to hepatocellular carcinoma, is common in this patient group.
Long term follow up studies have shown that transcatheter closure of perimembranous Ventricular Septal Defect (PmVSD) can be done safely and successfully. One of the most serious complications of VSD device closure is complete atrioventricular block which has been reported in 3-18% is various studies following VSD device closure. Amplatzar Duct Occluder II (ADO-II) device is now commonly being used for closure of small to moderate sized PmVSD. Complete heart block has not been reported with ADO-II device. We are reporting 2 cases of complete heart block following transcatheter closure of PmVSD using ADO-II device where sinus rhythm was established following early surgical removal of the device.
We recommend trans-thoracic real time three-dimensional echocardiography for the assessment of the congenitally malformed aortic valve, particularly to identify sites of fusion between leaflets and to measure the orificial diameter. The definition of nodularity, and the prognosis of nodules based on the mode of intervention, will need a comparative study of patients submitted to balloon dilation as well as those undergoing surgical valvotomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.