Aim: To evaluate the cyclic fatigue resistance of Reciproc blue (RB) 40/0.06 instruments tested at room temperature (20° ± 0.5°C) and at body temperature (37° ± 0.5°C) in a simulated stainless steel canal. Materials and methods: Twenty-four new RB 40/0.06 instruments were randomly divided into two groups (n = 12) according to the temperature used. Dynamic fatigue testing was performed using an artificial stainless steel canal with a 60° curvature angle and a 5-mm radius of curvature. The temperature was controlled throughout the experiment with an underwater thermometer and a thermostat. The data were analyzed descriptively using the IBM SPSS 23.0 program, considering p < 0.05. Results: The time to fracture of the RB instruments differed significantly between the two temperatures (1083.82 seconds at 20°C and 403.80 seconds at 37°C). No significant differences were found in fragment size.
Conclusion:An increase in temperature reduces the cyclic fatigue resistance of RB 40/0.06 instruments. The results of the study suggest that an intracanal cooling system can be favorable to the fracture resistance of the tested instruments. Clinical significance: A cooling system of the root canal system is important in endodontic as it favors the cyclic fatigue resistance of Ni-Ti instruments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.