Smoke inhalation is a common cause of cyanide poisoning during fires, resulting in injury and even death. In many cases of smoke inhalation, cyanide has increasingly been recognized as a significant toxicant. The diagnosis of cyanide poisoning remains very difficult, and failure to recognize it may result in inadequate or inappropriate treatment. Findings suggesting cyanide toxicity include the following: (a) a history of enclosed-space fire; (b) any alteration in the level of consciousness; (c) any cardiovascular changes (particularly inexplicable hypotension); and (d) elevated plasma lactate. The feasibility and safety of empiric treatment with hydroxocobalamin for fire smoke victims have been reported in the literature. On the basis of a literature review and a panel discussion, a group of European experts has proposed emergency management protocols for cyanide toxicity in fire smoke victims.
Summary: Background: Age-adjusted D-dimer cut-off has recently been proposed to increase D-dimer usefulness in older patients suspected of pulmonary embolism (PE). Objective: We externally validated this age-adjusted D-dimer cutoff using different D-dimer assays in a multicenter sample of emergency department patients. Methods: Secondary analysis of three prospectively collected databases (two European, one American) of patients suspected of having PE. D-dimer performance for ruling out PE was assessed by calculating negative likelihood ratio (nLR) for D-dimer with age-adjusted D-dimer cut-off (< age · 10 in patients over 50 years) and with conventional cut-off (< 500 lg dL ). Test efficiency was assessed by the number needed to test (NNT) to rule out PE in one patient. Results: Among 4537 patients included, overall PE prevalence was 10.1%. In the overall population, nLR was 0.06 (95% confidence interval, 0.03-0.09) with conventional cut-off and 0.08 (0.05-0.12) with age-adjusted cut-off. Using age-adjusted cut-off, nLR was 0.08, 0.09 and 0.06 for Vidas Ò , Liatest Ò and MDA Ò assays, respectively. Use of age-adjusted cut-off produced a favorable effect on NNT in the elderly; the greatest decrease was observed in patients > 75 years: NTT halved from 8.1 to 3.6. The proportion of patients over 75 years with normal D-dimer was doubled (27.9% vs. 12.3%). Conclusions: Our study shows that age-adjusted D-dimer had low nLR, allowing its use as a rule-out PE strategy in non-high pretest clinical probability patients, as well as using Vidas Ò , Liatest Ò or MDA Ò assays. This age-adjusted cut-off increased clinical usefulness of D-dimer in older patients. A large prospective study is required to confirm these results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.