To improve the quantitative representation of elastic recoil, an exponential function (V = A - B exp (-KP), where V is the lung volume, P is the recoil pressure, and A, B, and K are constants), has been fitted to static pressure-volume (PV) data by a least-squares technique using a digital computer. The PV points below about 50% total lung capacity (TLC) usually deviate from an exponential expression. Increasing the lower volume limit to which the exponential was fitted from 40 to 75% of TLC in 20 subjects, increased K and B/A significantly. Residual variance was lowest (approx 1.0 +/- 0.5%) when the lower volume limit was between 50 and 60% TLC. The PV points in the lower volume range deviated significantly less from exponential in a group of older subjects than for young subjects. The coefficient of variation of K and B/A for duplicate studies in 10 subjects was 9 and 14%, respectively. For inflation PV data, K was significantly lower and A significantly higher than for deflation. For PV data obtained after a submaximal inspiration, K did not change significantly. From this exponential function, the PV curve above 50% TLC can be satisfactorily described by K, B/A, and recoil pressure at TLC; other conventional parameters may be derived.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.