Introduction Computed tomography pulmonary angiography (CTPA) is the test of choice for diagnosis of pulmonary embolism (PE) in the emergency department (ED), but this test may be indeterminate for technical reasons such as inadequate contrast filling of the pulmonary arteries. Many hospitals have requirements for intravenous (IV) catheter size or location for CTPA studies to reduce the chances of inadequate filling, but there is a lack of clinical data to support these requirements. The objective of this study was to determine if a certain size or location of IV catheter used for contrast for CTPA is associated with an increased chance of suboptimal CTPA. Methods This was a retrospective chart review of patients who underwent CTPA in the ED. A CTPA study was considered suboptimal if the radiology report indicated it was technically limited or inadequate to exclude a PE. The reason for the study being suboptimal, and the size and location of the IV catheter, were abstracted. We calculated the rate of inadequate contrast filling of the pulmonary vasculature and compared the rate for various IV catheter sizes and locations. In particular, we compared 20-gauge or larger IV catheters in the antecubital fossa or forearm to all other sizes and locations. Results A total of 19.3% of the 1500 CTPA reports reviewed met our criteria as suboptimal, and 51.6% of those were due to inadequate filling. Patients with a 20-gauge IV catheter or larger placed in the antecubital fossa or forearm had inadequate filling 9.2% of the time compared to 13.2% for patients who had smaller IVs or IVs in other locations (difference: 4.0% [95% confidence interval, −1.7%–9.7%]). There were also no statistically significant differences in the rates of inadequate filling when data were further stratified by IV catheter location and size. Conclusion We did not detect any statistically significant differences in the rate of inadequate contrast filling based on IV catheter locations or sizes. While small differences not detected in this study may exist, it seems prudent to proceed with CTPA in patients with difficult IV access who need emergent imaging even if they have a small or distally located IV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.