In this study, the experiment to confirm the risks of particulate material was carried out as a precedent study for developing the toxicity evaluation method of combustion products including the toxicity of particulate material. In the experiment, the test result of filtering and exposing particulate material among combustion products and that of exposing combustion products including particulate material were compared and analyzed by analyzing changes in average movement stop time according to the installation of Membrane filter between the stirring box and test box through the gas toxicity test of the same specimen to filter particulate material among combustion products. As the test result, in case of installing a filter, the average movement stop time of an experimental rat increased by up to 264% in case of lumber specimen and up to 179% in case of urethane specimen. Through such result, the necessity of identifying the toxicity of particulate material and carrying out quantitative toxicity test for particulate material was confirmed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.