BACKGROUND: Managing massive bone defects, a great challenge to orthopaedics reconstructive surgery. The problem arise is the supply of suitable bone is limited with many complications. Tissue-engineered hydroxyapatite bone (TEHB) scaffold impregnated with osteoprogenitor cells developed as an alternative to promote bone regeneration. METHODS: This animal protocol has been approved by Universiti Kebangsaan Malaysia Animal Ethical Committee. The TEHB scaffold prepared from hydroxyapatite using gel casting method. A total of six adolescent female sheep were chosen for this study. Later, all the sheep were euthanized in a proper manner and the bone harvested for biomechanical study. Bone marrow was collected from iliac crest of the sheep and bone marrow stem cells (BMSCs) isolated and cultured. BMSCs then cultured in osteogenic medium for osteoprogenitor cells development and the plasma collected was seeded with osteoprogenitor cells mixed with calcium chloride. Bone defect of 3 cm length of tibia bone created from each sheep leg and implanted with autologous and TEHB scaffold in 2 different groups of sheep. Wound site was monitored weekly until the wound completely healed and conventional X-ray performed at week 1 and 24. Shear test was conducted to determine the shear force on the autologous bone and TEHB scaffold after implantation for 24 weeks. RESULTS: All of the sheep survived without any complications during the study period and radiograph showed new bone formation. Later, the bone harvested was for biomechanical study. The highest shear force for the autologous group was 13 MPa and the lowest was 5 MPa while for the scaffold group, the highest was 10 MPa and the lowest was 3 MPa. Although, proximal and distal interface of autologous bone graft shows higher shear strength compared to the TEHB scaffold but there is no significant difference in both groups, p value [ 0.05. Histologically in both proximal and distal interface in both arms shows bone healing and woven bone formation. CONCLUSION: TEHB scaffold impregnated with osteoprogenitor cells has the potential to be developed as a bone substitute in view of its strength and capability to promote bone regeneration.
Background To ensure the success of total knee arthroplasty (TKA), precise bone cuts and a well-balanced soft tissue envelope are crucial. Soft tissue release may be necessary, subject to various factors. Therefore, documenting the type, frequency, and necessity of soft tissue releases can establish a benchmark for comparing different alignment techniques and philosophies and evaluating their outcomes. The purpose of this study was to demonstrate that robotic-assisted knee surgery requires minimal soft tissue release. Methods We prospectively documented and retrospectively reviewed the soft tissue releases employed in securing ligament balance in the first 175 patients who received robotic-assisted TKAs at Nepean Hospital. ROSA was utilized in all surgeries with the aim of restoring mechanical coronal alignment, with a flexion gap balancing technique. Surgeries were performed between December 2019 to August 2021 by a single surgeon who used a standard medial parapatellar approach without a tourniquet, and the cementless persona prosthesis. All patients were followed up for a minimum of 6 months post-surgery. Soft tissue releases included any form of medial release for varus knee, posterolateral release for valgus knee and PCL fenestration or sacrifice. Results There were 131 female and 44 male patients, aged between 48 to 89 years (average 60 years). The preoperative HKA ranged from 22 degrees varus to 28 degrees valgus, with 71% of patients presenting with a varus deformity. For the whole group, the no need for soft tissue release was documented in 123 patients (70.3%), small fenestrated releases of PCL in 27 (15.4%), sacrifice of PCL in 8 (4.5%), medial releases in 4 (2.3%) and posterolateral releases in 13 (7.4%). In 29.7% of patients in whom a soft tissue release was necessary for balance, over half were/received minor fenestrations of the PCL. Outcomes to date included no revisions or impending revisions, 2 MUAs (1%), and Oxford knee scores averaged 40 at 6 months. Conclusion We concluded that Robot technology enhanced the precision of bone cuts and allowed for titration of required soft tissue releases to achieve optimal balance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.