Dynamic cerebral autoregulation (CA), the transient response of cerebral blood flow (CBF) to rapid changes in arterial blood pressure (BP), is usually modeled as a linear mechanism. We tested the hypothesis that dynamic CA can display nonlinear behavior resulting from differential efficiency dependent on the direction of BP changes. Cerebral blood velocity (CBV) (transcranial Doppler), heart rate (HR) (three-lead ECG), continuous BP (Finometer), and end-tidal CO (capnograph) were measured in 10 healthy young subjects during 15 squat-stand maneuvers (SSM) with a frequency of 0.05 Hz. The protocol was repeated with a median (interquartile range) of 44 (35-64) days apart. Dynamic CA was assessed with the autoregulation index (ARI) obtained from CBV step responses estimated with an autoregressive moving-average model. Mean BP, HR, and CBV were different (all P < 0.001) between squat and stand, regardless of visits. ARI showed a strong interaction ( P < 0.001) of SSM with the progression of transients; in general, the mean ARI was higher for the squat phase compared with standing. The changes in ARI were partially explained by concomitant changes in CBV ( P = 0.023) and pulse pressure ( P < 0.001), but there was no evidence that ARI differed between visits ( P = 0.277). These results demonstrate that dynamic CA is dependent on the direction of BP change, but further work is needed to confirm if this finding can be generalized to other physiological conditions and also to assess its dependency on age, sex and pathology.
Squat/stand maneuvers (SSM) have been used to assess dynamic cerebral autoregulation (dCA), but always at a fixed frequency (FF). This study aimed to assess the use of random-frequency (RF) SSMs as a stimulus for measuring dCA and determine the reproducibility of FF and RFSSMs. Twenty-nine healthy volunteers [19 male, mean age 23.0 (4.9) yr] completed the study; 11 returned for a repeat visit (median 45 days). Heart rate, beat-to-beat blood pressure, middle cerebral artery (MCA) blood flow velocity, end-tidal CO, and angle of the squat movement were measured. Subjects underwent four recordings: 5 min sitting, 5 min standing, FFSSMs (0.05Hz), and RFSSMs. Subjects were asked to rate the degree of exertion experienced while performing these maneuvers. Twenty-nine subjects completed the protocol; nine data sets were deemed unsuitable for further analysis. Mean ARI of 6.21 (1.04) while standing was significantly greater than during the SSMs ( < 0.01), with mean (SD) ARI during the FF and RFSSMs being 5.16 (1.43) and 5.37 (1.21), respectively. However, no significant difference was found between the ARI estimates from the two SSMs ( = 0.856) or for each of the four recordings between the two visits ( = 0.645). RFSSMs were found to be significantly less tiring than FFSSMs ( < 0.01). In conclusion, RFSSMs are an effective and noninvasive method of assessing dCA. There is no difference in the ARI estimates in comparison with FFSSMs. Although FFSSMs have been well tolerated previously, RFSSMs are preferred by healthy subjects and thus may be better tolerated by a patient population in a clinical setting. RFSSMs provided comparable estimates of autoregulatory indices to FFSSMs. Instead of point estimates at the driven frequency, RFSSMs generate a broader power spectrum of changes in arterial blood pressure and cerebral blood flow velocity, allowing direct comparison with spontaneous fluctuations through transfer function analysis. Moreover, random-frequency SSMs are preferred by participants. They are a novel tool by which larger blood pressure oscillations can be elicited for the reliable measurement of dynamic cerebral autoregulation.
PurposeSquat–stand manoeuvres (SSMs) have been used to induce blood pressure (BP) changes for the reliable assessment of dynamic cerebral autoregulation. However, they are physically demanding and thus multiple manoeuvres can be challenging for older subjects. This study aimed to determine the minimum number of SSMs required to obtain satisfactory coherence, thus minimising the subjects’ workload.Method20 subjects performed SSMs at a frequency of 0.05 Hz. End-tidal CO2, cerebral blood flow velocity, heart rate, continuous BP and the depth of the squat were measured. 11 subjects returned for a repeat visit. The time points at which subjects had performed 3, 6, 9, 12 and 15 SSMs were determined. Transfer function analysis was performed on files altered to the required length to obtain estimates of coherence and the autoregulation index (ARI).ResultsAfter three SSMs, coherence (0.05 Hz) was 0.93 ± 0.05, and peaked at 0.95 ± 0.02 after 12 manoeuvres. ARI decreased consecutively with more manoeuvres. ARI was comparable across the two visits (p = 0.92), but coherence was significantly enhanced during the second visit (p < 0.01). The intra-subject coefficients of variation (CoV) for ARI remained comparable as the number of manoeuvres varied.ConclusionsThis analysis can aid those designing SSM protocols, especially where participants are unable to tolerate a standard 5-min protocol or when a shorter protocol is needed to accommodate additional tests. We emphasise that fewer manoeuvres should only be used in exceptional circumstances, and where possible a full set of manoeuvres should be performed. Furthermore, these results need replicating at 0.10 Hz to ensure their applicability to different protocols.
Background: Squat-stand maneuvers (SSMs) have been used to improve the coherence of
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.