Treatment with the Ponseti method corrects congenital idiopathic clubfeet in the majority of patients. However, some feet do not respond to the standard treatment protocol. We describe the characteristics and treatment results of these complex idiopathic clubfeet. We identified 50 patients (75 clubfeet) from 762 consecutive patients treated at five institutions. Clinically, complex clubfeet were defined as having rigid equinus, severe plantar flexion of all metatarsals, a deep crease above the heel, a transverse crease in the sole of the foot, and a short and hyperextended first toe. The Achilles' tendon was exceptionally tight and fibrotic up to the middle of the calf. Correction was achieved in all patients by modifying the Ponseti manipulation and casting technique. Correction required an average of five casts (range, 1-10 casts). Two patients (4%) not initially recognized as having complex clubfeet had a posterior release with tendo Achillis lengthening. There were seven relapses that responded to casting. Three patients had a second tenotomy. Modifying the treatment protocol for complex clubfeet successfully corrected the deformity without the need for extensive corrective surgery.
The Pirani scoring system, together with the Ponseti method of club foot management, was assessed for its predictive value. The data on 70 idiopathic club feet successfully treated by the Ponseti method and scored by Pirani's system between February 2002 and May 2004 were analysed. There was a significant positive correlation between the initial Pirani score and number of casts required to correct the deformity. A foot scoring 4 or more is likely to require at least four casts, and one scoring less than 4 will require three or fewer. A foot with a hindfoot score of 2.5 or 3 has a 72% chance of requiring a tenotomy. The Pirani scoring system is reliable, quick, and easy to use, and provides a good forecast about the likely treatment for an individual foot but a low score does not exclude the possibility that a tenotomy may be required.
All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.
A ll surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty. [Br] 1999;81-B:886-9. J Bone Joint Surg
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.